摘要
传统的励磁回路采用线性电阻灭磁,间隙保护作为转子过电压保护,这种励磁接线具有很多缺点。目前,系统内已有许多机组采用高性能氧化锌电阻作为转子灭磁电阻和过电压保护,具有良好的实用效果。介绍了淮北发电厂5号机励磁回路技术改造情况和高能ZnO电阻的原理及其在励磁回路中的应用。
Traditional excitation circuit adopts linear resistant for demagnetization and clearance protection as rotor over voltage protection.It has many disadvantages.Now there are many sets in electric power system which adopt high performance zinc oxide resistance for rotor demagnetization and over voltage protection,and have good practical effects.The excitation circuit retrofitting of Huaibei Power Plant No.5 unit with ZnO is introduced.
出处
《电力自动化设备》
EI
CSCD
2000年第1期57-59,共3页
Electric Power Automation Equipment