摘要
采用252 Cf源中子诱发金属铀部件裂变的主动探测方法对铀部件质量识别进行探索,实验测量了3.8~15.2kg 8件高浓缩铀部件的源中子与探测器的互相关函数谱C12(τ),互相关函数谱积分值R12随铀部件质量有明显的变化规律。当铀部件质量为3.8~7.2kg时,质量灵敏系数为8.5%;铀部件质量为7.2~15.2kg时,质量灵敏系数为11.0%。
The source detector correlation functions of eight uranium metal with mass range from 3.8 to 15.2 kg were measured by 252Cf source induced fission analysis method.The integral of correlation functions evidently increases with fissile mass.The sensitivity coefficient of mass is 8.5% and 11.0% as the uranium mass is from 3.8 to 7.2 kg and from 7.2 to 15.2 kg,respectively.
出处
《原子能科学技术》
EI
CAS
CSCD
北大核心
2012年第6期754-757,共4页
Atomic Energy Science and Technology
关键词
铀质量
互相关函数
质量灵敏系数
uranium mass
correlation functions
sensitivity coefficient of mass