期刊文献+

高压架空输电线路的故障测距方法 被引量:102

A FAULT LOCATION METHOD FOR OVERHEAD HIGH VOLTAGE POWER TRANSMISSION LINES
下载PDF
导出
摘要 对高压架空输电线路进行准确的故障测距是保证电力系统安全稳定运行的有效途径之一。为此 ,文章比较全面地介绍了国内外在此方面的发展历程和研究现状。根据各测距算法采用的原理不同 ,将现有的各种测距算法分为行波测距、单端测距和双端测距三类 ,然后逐类对各种算法的理论基础和应用条件上进行了分析、对比和讨论 ,并在此基础上总结得出了各测距算法的优点及存在的问题 ,指出了每种测距算法的适用范围和应用局限性。最后 。 Because the accurate fault location for high voltage transmission line plays increasingly important role in power system, the development and general situation of the research in this field in China and in other countries is reviewed in this paper. All the existing algorithms can be classified into three main methods: traveling wave location, single terminal location and two terminal location, the principle and application condition of each algorithm are presented and discussed. Base on the analysis and comparison of each algorithm, the corresponding merits and application limitation are concluded. At last, the prospects in fault location are described.
出处 《电网技术》 EI CSCD 北大核心 2000年第4期27-33,共7页 Power System Technology
关键词 高压架空输电线路 故障测距 电网 HV overhead transmission line fault location algorithm
  • 相关文献

参考文献15

二级参考文献27

  • 1董新洲,葛耀中.一种使用两端电气量的高压输电线路故障测距算法[J].电力系统自动化,1995,19(8):47-53. 被引量:80
  • 2徐君峰,1986年
  • 3刘娟芝,1985年
  • 4蔡德礼,重庆大学学报,1982年,2期
  • 5索南加乐,1990年
  • 6葛耀中,继电器,1990年,1期
  • 7宋从矩,电力系统自动化,1989年,4期
  • 8索南加乐,电力系统自动化,1989年,4期
  • 9葛耀中,电力自动化设备,1989年,2期
  • 10梁懋,电力自动化设备,1989年,3期

共引文献200

同被引文献516

引证文献102

二级引证文献767