摘要 目的探讨分析全自动血型检测系统在血站血型检测中应用的可行性。方法使用Microlab Star8CH全自动加样系统加样、AK03A全自动数字血型分析仪判读,组成血型全自动化检测系统检测1 487份无偿献血者的ABO和Rh血型,从血型判读的符合率、混合血清样本倍比稀释后反定型检测灵敏度、溶血及脂血干扰试验4个方面进行分析。结果全自动血型检测系统血型判读符合率达99.7%;混合血清小于或等于1∶64的稀释度反定型检测准确度达100.0%,脂血和溶血标本对检测结果无影响。结论全自动血型检测技术具有较高的准确度,实现了血型检测标准化、自动化,适用于血站血型的批量检测。 Objective To discuss the application feasibility of automatic blood group detecting system in blood group check in the blood stations. Methods The Microlab Star 8CH full automation sampling system for adding sample and the fully automatic AK03A figure blood group analyser for interpretation were combined into the blood group full automation detecting system. This system was used to detect ABO and Rh blood group in 1 487 free blood donators. The analysis was performd in 4 aspects of the coincidence rate in blood group interpretation,the sensitivity of reverse typing detection after doubling dilution of mixed serum samples, hematolysis and lipidemia interference. Re- sults The coincidence rate interpreted by the blood group full automation detecting system reached 99.7%. The sen- sitivity of reverse typing detection of mixed serum dilution ≤ 1 : 64 reached 100%. The lipidemia and hematolysis specimens had no influence to the test results. Conclusion The full automation blood group testing technique has higher accuracy and capacity, and realizes the standardization and automation of blood group test, which is suitable for the blood group batch detection in the blood stations.
出处 《检验医学与临床》 CAS 2012年第12期1432-1433,共2页 Laboratory Medicine and Clinic
关键词 ABO血型 自动化检测 血浆 ABO blood group automation detecting plasma
  • 相关文献

参考文献5

二级参考文献12

  • 1季建兵,姜标.RhD血型初筛的自动化检测[J].临床输血与检验,2005,7(2):130-130. 被引量:2
  • 2胡继征,陆典瑞,李启辉,冯健亮.全自动微板法筛查献血者Rh血型D抗原的检测方法[J].河南科技大学学报(医学版),2005,23(4):250-251. 被引量:6
  • 3向东,刘曦,郭忠慧,周筱嫣,张嘉敏,沈伟.上海地区中国人群中ABO亚型的研究[J].中国输血杂志,2006,19(1):25-26. 被引量:100
  • 4Olsson ML, Chester MA. A rapid and simple ABO genotype screening method using a novel B/O2 versus A/O2 discriminating nucteotide substitution at the A BO locus. Vox Sang, 1995, 69 (3) :242- 247.
  • 5Ogasawara K, Yabe R, Uchikawa M, at el. Different alleles cause an imbalance in A2 and A2B phenotypes of the ABO blood group. Vox Sang, 1998, 74(4) :242-247.
  • 6中华人民共和国卫生部医政司.全国临床检验操作规程(第2版)[Z].,1997-1.103-105.
  • 7中华人民共和国卫生部.中国输血技术操作规程[Z].,1997.33.
  • 8丁苏鄂.常用血清学检查技术[M]//刘达庄.免疫血液学[M].上海:科学技术出版社,2002,195-196
  • 9倪旱雨.实验设计[M]//杨树勤.卫生统计学.第3版.北京:人民卫生出版社,1998,78-105
  • 10葛红卫,王鸿捷,韩卫,张爱红,汤玉泉.ABO血型自动化检测方法的建立[J].中国输血杂志,1998,11(2):63-65. 被引量:31

共引文献67

同被引文献15

引证文献2

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部