OrbscanⅡ角膜地形图测量不同屈光度近视角膜厚度的临床观察 被引量:1

Clinical observation on measuring different myopic diopter with orbscan Ⅱ corneal topography
原文传递
导出
摘要 目的评价裂隙扫描角膜地形图/角膜测厚系统在分析测量不同屈光度近视眼角膜厚度分布特征和应用价值。方法应用OrbscanⅡ角膜地形图测量55例(109眼)近视眼患者中心角膜厚度。结果高度近视眼与中低度近视眼在角膜中央区角膜厚度与近视屈光度上比较差异无统计学意义(P>0.05)。结论 OrbscanⅡ角膜地形图能方便、准确、无创地测量不同屈光度近视全角膜厚度,应用于屈光手术术前、术后检查,用以指导制订手术方案、排除圆锥角膜等手术禁忌证,在角膜基础研究领域具有广泛的应用前景。 Objective To evaluate the application value of distribution characteristics in cornea thickness of myopia by using Orbscan corneal topography system.Methods The central corneal thickness of myopia in 55 cases(109 eyes) were measured by Orbscan corneal topography system.Results There were no significant differences in central corneal thickness and diopter between high myopic eyes and low to moderate myopic eyes(P〉0.05).Conclusion Orbscan corneal topography system is a noninvasive and accurate test which can conveniently be used to measure different corneal thickness of myopic diopter.Using in the preoperative and postoperative examination of refractive surgery,it can guide to establish the operation scheme,exclude of keratoconus and other operation contraindications.It has wide application prospects in the basic research of cornea.
出处 《临床医学》 CAS 2012年第5期31-32,共2页 Clinical Medicine
关键词 OrbscanⅡ角膜地形图 角膜厚度 不同屈光度近视 Orbscan Ⅱ topography Corneal thickness Different diopter of myopia
  • 相关文献

参考文献3

二级参考文献4

  • 1李凤鸣.眼科全书[M].北京:人民卫生出版社,1997.2421.
  • 2Salz J J,et al.A calculation and comparison of source of variability in the measurement of corneal thickness with ultrasonic and optical pachymeters[].Ophthalmic Surgery.1983
  • 3Thornton S P.A guide to pachymeters[].Ophthalmic Surgery.1984
  • 4杜之渝,张大勇,郑晴,陈曜,郭红,尹宏民.Orbscan角膜地形图系统测量误差的分析[J].中华眼科杂志,2003,39(1):36-40. 被引量:13

共引文献8

同被引文献9

  • 1宋小康,桂曼芸,何书喜,刘伟.Orbscan-Ⅱ角膜地形图筛查早期圆锥角膜的研究[J].实用诊断与治疗杂志,2007,21(10):734-736. 被引量:6
  • 2Elbaz U,Barkana Y,Gerber Y,et al.Comparison of different tech-niques of anterior chamber depth and keratometric measurements[ J].Am J Ophthalmol,2007,143(1):48-53.
  • 3Srivann aboon S,Reinstein DZ,Sutton H F,et al.Accuracy of Orb-scan total optical maps in detecting refractive change after myopic laser in situ keratomileusis [ J ].J Cataract Reract Surg,1999,25(12):1596-1599.
  • 4Sonego-Krone S,Lopez-Moreno G,Beaujon-Balbi OV,et al.A di-rect method to measure the power of the central cornea after myopic la-ser in sitn keratomileusis [ J ].Arch Ophthahnol,2004,22(2):159-166.
  • 5Nemeth G,VajaSA,Tsorbatzoulon A,et al.Assessment and repro-ducibility of anterior chamber depth t with anterior seg-ment optical coherence tomography compared with immersion ultra-sonography[ J ].J Cataract Refract Surg,2007,33(3):443-447.
  • 6Chen YA,Hirnschall N,Findl O.Evaluation of 2 new optical bion-metry devices and comparison with the current gold standard biometer [J].J Cataract Refract Surg,2011,37(3):513-517.
  • 7胡俊,李学喜,林巧雅,叶瑞珍,许敏.不同仪器测量角膜直径和角膜曲率的一致性评价[J].眼科新进展,2012,32(4):372-375. 被引量:11
  • 8沈政伟,薛林平,莫婷,尹禾,姜黎.Lenstar LS900的临床应用进展[J].国际眼科杂志,2012,12(11):2123-2125. 被引量:12
  • 9李翔,庞辰久,彭海鹰,戴丽娟,孟志红,鲁传琴.Orbscan-II、IOL Master和Atlas角膜地形图测量角膜直径的比较[J].眼科新进展,2012,32(11):1061-1063. 被引量:9

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部