摘要
目的采用HPLC法测定盐酸氨溴索注射液中的有关物质。方法采用Agela Venusil MPC18柱(250mm×4.6mm,5μm),以磷酸氢二铵缓冲液(pH4.0)-甲醇(40:60)为流动相,体积流量为1.0mL/min,检测波长为250nm,柱温:30℃。结果盐酸氨溴索和反式-4-[6,8-二溴-1,4-二氢喹唑啉-3(2H)]环己醇的最小检出限分别为15、30ng;杂质的线性范围为0.72~1.68μg/mL(r=0.9996),加样平均回收率为101.32%,RSD为0.92%(n=9)。结论该方法测定盐酸氨溴索注射液中的有关物质方法简便、准确、专属性强。
Objective To develop a method for the determination of related substances in Ambroxol Hydrochloride Injection.Methods The analysis was performed on an Agela Venusil MP C18 column(250 mm×4.6 mm,5 μm).The mobile phase was ammonium dibasic phosphate buffer(pH 4.0)-methanol(40:60) with flow rate at 1.0 mL/min.The detection wavelength was 250 nm and column temperature was 30 ℃.Results The minimum detection limit of ambroxol hydrochloride and trans-4-[[(2-amino-3,5-dibromo-phenyl) methyl] amino]-cyclohexanol was 15 ng and 30 ng,respectively.The calibration curve of impurity was linear in the range of 0.72—1.68 μg/mL(r=0.999 6);An average recovery rate of 101.32% was obtained with RSD 0.92%(n=9).Conclusion This method is simple,accurate and with good specificity and could be used to determine the related substances in Ambroxol Hydrochloride Injection.
出处
《现代药物与临床》
CAS
2012年第3期226-228,共3页
Drugs & Clinic
基金
"十二五"重大新药创制科技重大专项项目(2011ZX09201-101-19)
国家重点基础研究发展计划项目(2010CB735602)