单片机在变水头法标定系统中的PID控制

The PID control of calibrating system with variable water head by microcontroller
下载PDF
导出
摘要 随着工业生产大型化,大口径大流量测量日益增加,为了使变水头大流量装置更精确的应用于大口径大流量的测量中,利用单片机能够实现PID调节的关键技术,能够在在标定过程中当高位槽中液位下降,调节阀的开度也随着增加,从而使得流量保持在一个恒定的状态。由于采用了利用流体自由降落和阀门动态调节流量的关键技术,解决了恒水头法标定过程中水泵必须向水流量标准装置持续注水以保持压头不变的过程,节省了大量的电力资源,是一种方便并且节约的一种新的标定方法。 As the industrial production becomes a large-scale, the measurement of large diameter and big flow increases gradually to make a more precise application used Variable faucet large flow device.We use the microcontroller to realize PID regulations,which can ensure the flow remaining a constant state by opening the valve a bit when the level of the high slot decreases.h's a new conve- nient calibration of high performance by applying the technology of fluid free falling and valve's flow dynamic adjusted,which can not only solve the problem that pumps should inject water to keep the pressure unchanged in the calibration ,but also save a large amount of power resources.
作者 孙红 王忠伟
出处 《微计算机信息》 2012年第6期90-91,共2页 Control & Automation
关键词 单片机 PID控制 大流量装置 变水头法标定系统 控制参数 Microcomputer PID Controller Large Flow Device Variable Faucet Method Calibration System Control parameters
  • 相关文献

参考文献9

  • 1韩伟.LSJ-300型静态容积法、标准表法水流量标准装置应用于分析.大庆油田有限公司,2007.
  • 2梁国伟.蔡武昌.流量测量技术及仪表.北京机械工业出版社,2002.6.
  • 3王新菱,郝斌,韩永和,夏爱武,王晓梅.静态容积法水流量标准装置的自动化研制.湖北南星化工总厂.2010.
  • 4赵学端,郑荣根.变水头大流量标准装置系统的数值分析[J].上海理工大学学报:社会科学版.
  • 5邵裕森,巴筱云.过程控制系统及仪表[M].北京:机械工业出版社,2005.
  • 6余雷声,方宗达.电气控制与PLC应用[M].北京:机械工业出版社,2001.10
  • 7王荣杰,陈超.威尔泰变水头大流量标准装置[J].上海计量测试,2003,30(4):21-22. 被引量:4
  • 8杨立保,许忠仁.组态软件实时数据库的研究与设计[J].自动化仪表,2009,30(8):19-21. 被引量:6
  • 9梁国伟,盛健.流量仪表等精度传递的实验研究和准确度分析[J].自动化仪表,2001,22(3):4-6. 被引量:11