摘要
依据GB/T18204.13-2000和GB/T18204.14-2000的规定,结合有温度、湿度要求的室内空间或各类实验室的实际内部环境情况,使用温场测量记录仪,重点布放在其有效工作区域内,对室内环境温湿度的均匀度、波动度、偏差的测量及试验数据的论证,确定该检测方法具有实用性和可行性。
In accordance with the provisions of GB/T 18204.13-2000 and GB / T 18204.14-2000, combined with the temperature, the interior space and humidity requirements or various types of laboratory internal environmental conditions, focusing cloth on its effectiveness, the use of the temperature field measurement recorderwork area, indoor environmental temperature and humidity uniformity, volatility, demonstration of the deviation of measurement and test data, to determine if the detection method. Demonstration of the data, this detection method has the practicality and feasibility.
出处
《上海计量测试》
2012年第3期36-38,共3页
Shanghai Measurement and Testing
关键词
温度
湿度
波动度
均匀度
偏差
temperature: humidity
volatility
uniformity
deviation