摘要
选取上海市松江安居小区、松江普通居民小区和市区普通居民小区的历史数据,通过分析各个小区的负荷增长趋势、年最大日峰谷差率、年平均日负荷率、年最大负荷利用小时数以及分季典型日标幺负荷曲线等多个负荷特性指标,研究松江安居小区的负荷特性及其与普通居民小区的异同。
Abstract:This paper selects the historical data of Songjiang affordable housing project quarters, Songjing general residential quarters and Shanghai urban general residential quarters as research basis. Many power load characteristic indicators are analyzed respectively for the different residential quarters, such as power load increase trend, annual maximum daily peak-valley difference rate, annual daily average load rate, annual peak load hours, and typical quar- terly Q load curve. Thereby, the differences in the load characteristics between Songjiang affordable housing project quarters and general residential quarters can be studied.
出处
《华东电力》
北大核心
2012年第6期1064-1066,共3页
East China Electric Power
基金
国家重点基础研究发展计划(2009CB219703)~~
关键词
负荷特性
电力规划
安居工程小区
power load characteristics
power planning
affordable housing project quarter