摘要 目的观察两种含添加剂的真空采血管和普通真空采血管对临床生化分析结果的差异,评价其在临床生化检验中的应用价值。方法采集同一供血者肘前正中静脉血,分别置于普通真空采血管(无任何添加剂)、含促凝剂的真空采血管和含分离胶的真空采血管中,采用日立7180生化分析仪在2 h内进行30项常规生化项目测定,并对结果进行比较分析。结果含促凝剂的真空采血管血清钾、乳酸脱氢酶、α-羟丁酸脱氢酶与普通真空采血管比较差异有统计学意义(P<0.05);含分离胶的真空采血管白蛋白与普通真空采血管比较差异有统计学意义(P<0.05)。结论含添加剂的真空采血管对于某些生化项目结果有影响,使用前应对真空采血管进行评估,采用影响较小的真空采血管,以保证实验结果的准确性。 Objective Result differences were investigated between the vacuum test tube containing two additives and the ordinary vacuum test tube's analysis on clinical biochemistry and their using value was judged on clinical biochemistry examination. Methods The same blood supplier on front median vein got collected, one stitch three tubes, the blood was put into the ordinary vacuum test tube (no additives),vacuum test tube containing coagulation accelerator and vacuum test tube containing separation gel separately. Adopting HITACHI 7180 to evaluate 30 clinical Routine Biochemistry items and analysis whether their test result difference has statistical significance or not.Results Comparing with ordinary vacuum test tube, the serum potassium, lactate dehydrogenase (LDH), alpha-hydroxybutyric in vacuum test tube containing coagnlation accelerator, dehydrogenase (HBDH) hadstatisticalsignificance ( P〈0.05 ). Comparing with ordinary vacuum test tube, the albumin (ALB)in vacuum test tube containing coagulation accelerator, dehydrogenase (HBDH) had statistical significance.Conclusion Vacuum test tube containing additives would affect some clinical Biochemistry test result items, it needs to evaluate the vacuum test tube before use and adopt the less effect vacuum test tube.
机构地区 丹阳市中医院
出处 《基层医学论坛》 2012年第16期2133-2134,共2页 The Medical Forum
关键词 真空采血管 分离胶促凝剂 生化结果 分析比较 Vacuum test tube Separation gel Coagulation accelerator Chemical result Analysis andcomparison
  • 相关文献

参考文献3

二级参考文献21

  • 1张海鹏,张燕萍.血液学检验中的安全问题[J].中华检验医学杂志,1998,22(3):50-52. 被引量:40
  • 2马雅静,谷杨,张蕾.不同采血管对PT、APTT及FIB检测的影响[J].农垦医学,2004,26(3):203-204. 被引量:3
  • 3李振有 陈礼明 等.实验室数据的临床应用[M].天津:科技翻译出版公司,2000.18-22.
  • 42 Kazunori M,Hirshi S,Kazumi S.Blood separation composition,EP,537,507(1993)
  • 5丛玉隆 孙芾.当代血液学分析[M].北京:人民卫生出版社,1998.34-36,91.
  • 6胡望平.用2,4-二氯酚色原酶法分析胆固醇[J].中华医学检验杂志,1984,7(2):84-84.
  • 7Imafuku Y,Meguro S,Kanno K,et al.The effect of EDTA contaminated in sera on laboratory data.Clin Chim Acta[J],2002,325(1 -2):105-111
  • 8Toffaletti JG,Wildermann RF.The effects of heparin anticoagulants and fill volume in blood gas syringes on ionized calcium and magnesium measurements.Clin Chim Acta[J],2001,304(1 -2):147-151
  • 9胡望平.血浆游离血红蛋白.见:总后卫生部编.医疗护理技术操作常规[M].第4版.1998:1847
  • 10孙艳,胡望平.测定血尿2,4-二氯酚法的建立及其临床应用:[硕士论文].福州:福建医科学大学,2004.10-12

共引文献83

同被引文献17

引证文献3

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部