摘要
对高温工况下钢结构以弹性变形与蠕变理论进行设计计算作了实例比较 ,结果表明 :对超过蠕变温度的构件应按蠕变理论计算 ;对低于蠕变温度工作的构件则应按规范的弹性理论计算。
In design calculation on steel structure part working at high temperature, design calculation with creep theory was compared to design calculation with elastic deformation theory. Results showed that design of steel structure part working at creep temperature up must be calculated with creep theory, design of steel structure part working at creep temperature down must be calculated with elastic deformation theory.
出处
《湖南冶金》
2000年第1期27-29,共3页
Hunan Metallurgy
关键词
蠕变
弹性变形
高温工况
钢结构
设计
steel structure part, creep ,creep temperature, elastic deformation