期刊文献+

生物摩擦学及表面工程的研究现状和进展 被引量:7

Current Situation and Development of Bio-tribology and Surface Engineering Research
下载PDF
导出
摘要 综述了生物摩擦学及表面工程的研究现状,并以人工关节、内固定、种植义齿和人工心脏瓣膜为例,探讨了不同人工器官的失效机理和采用的延寿措施,在此基础上,对今后的工作提出了一些建议。 Current situation and development of bio-tribology and surface engineering research have been reviewed in this paper. Failure mechanism of some artificial organs, such as artificial joint, rigid skeletal fixation, implant denture and artificial heart valve were introduced, and palliative methods for increasing the service life reported in the literature were examined. Based on the above review, some suggestions for the further studios have been made as well.
出处 《中国表面工程》 EI CAS CSCD 2000年第1期6-10,共5页 China Surface Engineering
基金 本项目受国家杰出青年科学基金资助!(59725513)
关键词 生物摩擦学 人工器官 生物材料 表面工程 bio-tribology, biomaterials, artificial organs, surface engineering
  • 相关文献

参考文献10

  • 1[1]Halling J. Principles of Tribology, London: The Macmillan Press LTD 1975, 1~3
  • 2[5]Wang A, Essner A, Stark C, et al. A biaxial line-contact wear machine for the evaluation of implant bearing materials for total knee joint replacement. Wear (225~229 ) : 701~707
  • 3[8]Besong A A, Hailey J L, Ingham E, et al. Influence of the combined effects of counterface roughness and ageing following gamma in air on the wear of UHMWPE. World Tribology Congress. London: 1997, 243
  • 4[15]Teruo Murakami, Hidehiko Higaki, Yoshinori Sawae. The adaptive multimode lubrication in natural synovial joints and artificial joints. World Tribology Congress. London: 1997 , 251
  • 5[31]Rostlund T, Albrektsson B, Albrektsson T. Wear of ion-implanted pure titanium againsg UHMWPE. Biomaterials 1989, 10:176~81
  • 6[36]Zachariades N,Papademetriou I,Rallis G. Complications associated with rigid internal fixation of facial bone fractures. J Oral Maxillofac Surg. 1993, 51: 275~278
  • 7[37]Goodacre C J, Kan J Y K, Rungcharassaeng k. Clinical complication of osseointegrated implants. J Prosthet Dent 1999, 81(5): 537~52
  • 8[40]Hudson J D, Goldstein G R, Georgescu M. Enamel wear caused by three different restorative materials. J Prosthet Dent 1995, 74 (6): 647~54
  • 9[43]Per Derand, Peter Vereby. Wear of low-fusing dental porcelains. J Prosthet Dent 1999, 81(4): 460~3
  • 10[47]Huang N, Yang P, Xuan C, et al, Research on blood compatibility of amorphous titanium oxide films synthesized by ion beam enhanced deposition, Biomaterials, 1998, 19(7~9):761

同被引文献51

引证文献7

二级引证文献33

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部