期刊文献+

EGTA滴定法测定硅钙钡合金中钙钡方法的研究 被引量:1

Research on the Determination of Ca and Ba in Si-Ca-Ba Alloy by EGTA Titration
下载PDF
导出
摘要 试样以硝酸-氢氟酸溶解,高氯酸冒烟除尽硅和氟,用稀盐酸溶解盐类后制取母液。分取一定量母液两份,以三乙醇胺半胱氨酸联合掩蔽铁等干扰元素,以氢氧化钾调节pH≥13。第一份母液,钙黄绿素为指示剂,用EGTA标准溶液滴定钙钡合量,另一份母液在相同条件下以硫酸钾沉淀钡后,用EGTA标准溶液滴定钙量,用差减法计算钡的百分含量。测定结果令人满意,钙相对标准偏差小于0.31%,钡小于0.37%。 The sample was dissolved by nitrate acid and hydrofluoric acid, silicon and fluoride were removed by smoking perchloric acid, then the mother solution was prepared through dissolving salts with dilute hydrochloric acid. Two parts of mother solution was taken separately, and after masking the interferences such as Fe through combining triethanolamine and cysteine, the solution was regulated to pH ≥13 by KOH. For first part of mother solution, taking calcein as indicator, the content of Ca and Ba was titrated by EGTA standard solution; for another part of mother solution, under the same conditions, Ba was precipitated by potassium sulfate, the content of Ca was titrated by EGTA standard solution, and the content of Ba was calculated by subtraction method. Then the determination result was satisfactory, and according to the standard, the deviation of Ca less than 0. 31% and the deviation of Ba less than 0. 37%.
机构地区 技术中心
出处 《莱钢科技》 2012年第3期65-67,共3页 Laigang Science & Technology
关键词 硅钙钡合金 碱性介质 EGTA滴定法 Si-Ca-Ba alloy alkaline medium EGTA titration
  • 相关文献

参考文献6

二级参考文献5

  • 1滕梅,邢卫红,张秉英,高峰.钢包喂线──提高钢质量的重要途径[J].钢铁研究学报,1994,6(2):20-26. 被引量:12
  • 2YB/T053-93.铁钙包芯线的化学成分[S].[S].,..
  • 3华中师范学院.分析化学实验[M].北京:高等教育出版社,1986..
  • 4周庆余.工业分析综合实验[M].北京:化学工业出版社,1993..
  • 5GB6730.13-86.铁矿石化学分析方法高锰酸钾容量法测定钙量[S].[S].,..

共引文献65

同被引文献14

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部