摘要 为掌握目前气象行业使用的湿敏电容湿度传感器的测量准确度、迟滞误差、温度系数等测量特性,文章对3种不同型号的湿度传感器进行了测试,对不同温度点下传感器的相对湿度测量示值误差和迟滞误差进行了分析和比较,测试和分析结果表明不同传感器的温度和迟滞特性有较大的差异。其分析比较的结果对湿度传感器的选择和使用具有参考价值。 In order to understand measuring characteristics of capacitive humidity sensor such as accuracy, hysteresis and temperature coefficient, this paper tests three different capacitive humidity sensors. The errors of measurement value and hysteresis are compared under different temperature conditions. The results indicate that there are quite differences on temperature and hysteresis among these three sensors, which is available for the choice and use of capacitive humidity sensors.
出处 《气象水文海洋仪器》 2012年第2期11-15,共5页 Meteorological,Hydrological and Marine Instruments
关键词 湿敏电容 传感器测试 温度特性 迟滞特性 capacitive humidity sensor sensor testing temperature characteristic hysteresis
  • 相关文献

参考文献8

二级参考文献15

  • 1朱乐坤,温晓清.湿度表(计)检定装置不确定度分析[J].气象科技,2005,33(4):370-372. 被引量:17
  • 2朱乐坤,郑丽春.自动气象站各要素传感器检定结果的不确定度分析[J].应用气象学报,2006,17(5):635-642. 被引量:53
  • 3中国气象局.Ⅱ型自动气象站行业标准[S].北京:气象出版社,2000.
  • 4国家质量监督检验检疫总局.通用计量术语及定义[M].北京:中国计量出版社,1999.
  • 5Humidity sensing module using HS1100/HS1101 sensor.法国Humirel公司, HPC015VA/December 1999:5 - 8.
  • 6袁希光.传感器技术手册[M].北京:国防工业出版社,1992.93-110.
  • 7李干英,范金鹏.湿度测量[M].北京:气象出版社,1990.
  • 8Story P R, Galipeau D W, Mileham R D. A study of low cost sensors for measuring low relative humidity[J]. Sensors Actuators B.1995, 25: 681-685.
  • 9Das P, Lanzl C, Barone D. A surface acoustic wave transmitting hydrophone[J]. IEEE Ultrasonics Symp. 1978, 458-463.
  • 10Wohltjen H. Surface acoustic wave probe for chemical analysis[J]. Anal. Chem. 1979 , 51:1458-1475.

共引文献54

同被引文献68

引证文献10

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部