摘要 混凝土屋面防水维修时,如不拆除原防水层而采用聚氨酯防水涂料外露工法,易出现涂膜防水层起鼓发泡等现象。本文提出了自粘通气施工方法,利用自粘通气垫层作通气缓冲层,做成的聚氨酯外露防水层适合各种气温和湿度条件下的现场施工,是目前外露防水翻修工程的理想选择之一。 The waterproofing layer would bubble when polyurethane waterproofing coating is adopted to repair concrete roof without removing the original waterproofing layer. The paper introduces a construction method c, alled self-adhered ventilation which uses self-adhered ventilation cushion as ventilation buffer in order to make polyurethane waterproofing coating workable under different temperature and humidity. The method is a proper option for exposed watcrproofing retrofit at present.
出处 《中国建筑防水》 2012年第12期13-17,共5页 China Building Waterproofing
关键词 混凝土屋面翻修 外露型聚氨酯防水涂料 自粘通气缓冲垫层 粘结强度 通气度 耐疲劳性 concrete roof retrofit exposed polyurethane waterproofing coating self-adhered ventilation cushion bond strength venting quality fatigue resistance