摘要 目的对比三Endobutton技术解剖重建喙锁韧带与改良Weaver-Dunn术式的生物力学表现。方法 12具新鲜冰冻尸肩,分别从前、后及上3个方向对标本施加70 N应力,测量锁骨相对于肩胛骨的位移,完成后以25 mm/min的速率向上进行破坏试验,记录破坏负荷及断裂模式。将标本随机分为Endobutton组和改良Weaver-Dunn组,分别进行三Endobutton重建和改良Weaver-Dunn重建,重建后进行移位试验和破坏试验,比较不同情况下肩锁关节稳定性和力学强度。结果 Endobutton组比改良Weaver-Dunn组向前((8.72±1.41)mm vs(37.03±5.05)mm)及向后((8.03±3.68)mm vs(14.85±1.89)mm)的移位更小(P<0.05),与重建前喙锁韧带完整时(向前(7.81±2.22)mm,向后(7.16±1.95)mm)接近。向上移位各组间无明显差异。改良Weaver-Dunn组的破坏负荷为(172±9)N,明显低于Endobutton组(687±115)N和韧带完整组(685±234)N(P<0.05)。结论三Endobutton解剖重建喙锁韧带较改良Weaver-Dunn术式向前、向后移位更小,稳定性更接近于原完整韧带,且强度与喙锁韧带相近,能更好地恢复喙锁韧带的功能。 Objective To compare the biomechanical behavior of a triple Endobutton technique for anatomic reconstruction of coracoclavicular ligament and with a modified Weaver-Dunn procedure. Methods Twelve fresh frozen cadaveric shoulders were applied with 70 N in superior, anterior and posterior direction, respectively, to measure displacement of the acromioclavicular joint. The failure test with the load at the rate of 25 mm/min was conducted to record the failure load and failure mode. The specimens were then randomly assigned to 2 groups the triple Endobutton technique group and the modified Weaver-Dunn procedure group for reconstruction and to conduct displacement test and failure test again. The stability and mechanical strength of acromioclavicular joints after reconstruction under different states were then compared. Results The triple Endobutton technique group had significantly less anterior ( (8.72 ±1. 41 ) mm vs (37.03 ± 5.05) mm) and posterior ( (8.03 ± 3.68) mm vs (14.85±l. 89) mm) displacement than that in the modified Weaver-Dunn procedure group after reconstruction ( P〈0.05), and the former had similar displacement ( (7.81 ±2.22) mm anterior and (7.16 ±1.95) mm postedor) as compared to the intact state. There were no significant differences in superior displacement among the groups. The modified Weaver-Dunn procedure group had significantly smaller failure loads ( (172 ± 9) N) than that in the triple Endobutton technique group ( (687 ±115) N) and the intact ligament group ( (685 ±234) N) ( P 〈 0.05). Conclusions The triple Endobutton technique has less anterior and posterior displacement and its sta- bility is more closely approximate to the intact ligament; meanwhile, it has similar strength as coracoclavicular ligaments, which can better restore the function of coracoclavicular ligaments.
出处 《医用生物力学》 EI CAS CSCD 北大核心 2012年第3期333-338,共6页 Journal of Medical Biomechanics
基金 上海市卫生局科研课题基金(2009087)
关键词 解剖重建 Endobutton技术 Weaver-Dunn术式 稳定性 破坏负荷 Anatomical reconstruction Endobutton technique Weaver-Dunn procedure Stability Failure loads
  • 相关文献

参考文献20

  • 1Bishop JY,Kaeding C. Treatment of the acute traumatic acmmioclaviclular separation[J].Sports Medicine and Arthroscopy Review,2006,(04):237-245.
  • 2Smith TO,Chester R,Pearse EO. Operative versus non-operative management following Rockwood grade Ⅲ acromiociavicular separation:A meta-analysis of the current evidence base[J].JOURNAL OF ORTHOPAEDICS AND TRAUMATOLOGY,2011,(01):19-27.
  • 3Geaney LE,Miller MD,Ticker JB. Management of the failed AC joint reconstruction:Causation and treatment[J].Sports Medicine and Arthroscopy Review,2010,(03):167-172.
  • 4Koukakis A,Manouras A,Apostolou CD. Results using the AO hook plate for dislocations of the acromioclavicular joint[J].EXPERT REVIEW OF MEDICAL DEVICES,2008,(05):567-572.
  • 5Thomas K,Litsky A,Jones G. Biomechanical comparison of coracoclavicular reconstructive techniques[J].American Journal of Sports Medicine,2011,(04):804-810.
  • 6Liu HH,Chou Y J,Chen CH. Surgical treatment of acute acromioclavicular joint injuries using a modified Weaver-Dunn procedure and clavicular hook plate[J].Orthopedics,2010,(08):552.
  • 7张峻,王友,孙月华,戴尅戎,安丙辰.Endobutton治疗肩锁关节脱位术后复位丢失与固定装置力臂的相关性研究[J].医用生物力学,2011,26(5):476-481. 被引量:9
  • 8Dawson PA,Adamson G J,Pink MM. Relative contribution of acromioclavicular joint capsule and coracoclavicular ligaments to acromioctavicular stability[J].Journal of Shoulder and Elbow Surgery,2009,(02):237-244.
  • 9Lee kN,Debski RE,Chen CH. Functional evaluation of the ligaments at the acromioclavicular joint during anteroposterior and superoinferior translation[J].American Journal of Sports Medicine,1997,(06):858-862.
  • 10张东升.数字图像相关测量技术及其应用[J].医用生物力学,2009,24(2):85-88. 被引量:26

二级参考文献28

  • 1张东升,罗淼,韩永胜.材料力学性能显微测试系统[J].实验力学,2006,21(5):651-654. 被引量:10
  • 2Chu TC, Ranson WF, Sutton MA et al. Applications of digital image correlation techniques to expedmental mechanics[J]. Experimental Mechanics, 1985, 25 (3): 232- 244.
  • 3Bruck HA, McNeil, SR., Sutton MA., et al. Digital Image Correlation using Newton-raphson method of partial differential correction [J]. Experimental Mechanics, 1989, 29:261-267.
  • 4Zhang D, Arola D. A New Fast-search Strategy for Digital Image Correlation [ M]. Proc. SEM Annual Conference on Theoretical, Expedmental and Computational Mechanics, Milwaukee, Wisconsin, June 10-12, 2001, No. 80.
  • 5Althof R J, Wind MG., Dobbins JT. Rapid and automatic image registration algorithm with subpixel accuracy [J]. IEEE Transactions on Medical Imaging, 1997, 16(3):308- 316.
  • 6Hou Zhende Qin Yuwen. A study of fractal interpolation method [J].The International Society for Optical Engineering, 2001,4537:386-389.
  • 7Sutton Michael A, Chao Yuh J. Measurement of strains in a paper tensile specimen using computer vision and digital image correlation. Part 1 : data acquisition and image analysis system[J]. Tappi Journal, 1988, 71 ,(3):173-175.
  • 8Schreier HW, Braasch JR. ,Sutton MA. Systematic errors in digital image correlation caused by intensity interpolation [J].Optical Engineering, 2000,39(11 ):2915-2921.
  • 9Pan B, Xie H, Wang Z,etal.Studyon subset size selection in digital image correlation for speckle patterns [J].Optics Express, 2008,16,(10): 7037-7048.
  • 10Zhang D, Luo M ,Arola D. Displacement / Strain Measurements using an optical microscope and digital image correlation[J]. Optical Engineering, 2006,3: 033605- 033710.

共引文献33

同被引文献21

引证文献5

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部