摘要
介绍因循环机振动大,采取增大进、排气缓冲器后仍不能改善的原因。分析认为振动大是由于气柱共振导致的,采取隔断气柱等措施后,振动减轻,压缩机运行状况得到极大改善。
Increasing the intake buffer and exhaust buffer still can not improve the circulation machine vibration. Analyze the problem, vibration is due to air column resonance. After taking measures of separating air column etc., the vibration is reduced, the compressor operating conditions have been greatly improved.
出处
《化工设计通讯》
CAS
2012年第3期63-67,共5页
Chemical Engineering Design Communications
关键词
循环机
管路振动
气柱共振
缓冲器
circulation machine
piping vibration
air column resonance
buffer