摘要 目的分析放疗中x线的高次散射对剂量计算结果的影响,解决将2次散射光子及高次散射光子对剂量贡献问题修正到1次散射光子散射剂量贡献中的可能性,为建立快速蒙特卡罗剂量计算方法提供支持。方法采用x线与物质的作用截面理论和蒙特卡罗方法计算结果,分析1次、2次和高次散射X线对剂量计算精确度影响相对重要性。结果≥2次的高次散射对剂量的影响很小,并且可通过一小的修正系数被修正到1次散射X线的贡献中。结论只追踪原射线和1次散射X线剂量贡献就可获得临床满意的剂量计算精确度,如用蒙特卡罗方法建立1次散射x线散射光子注量角分布和光子平均能量散射角分布模型数据库,将有助于提高临床剂量的蒙特卡罗计算效率。 Objective To analyze the effects of high-order scattered X-ray in dose calculation in radiotherapy, to resolve the problem of correcting the dose contribution of secondary and high-order scattering X-ray to the primary scattered X ray, and to provide a support for photon fast dose calculation method of Monte Carlo. Methods By the theory of cross-section in interaction between X-ray with material and Monte Carlo calculating resuhs, to analysis the relative importance of primary scattered X-ray, secondary and high- order scattered of X-ray in dose calculation. Results The contribution of secondary and high-order scattered X-ray to dose calculation was very small, it can be corrected to the primary scattered X-ray with a correction factor. Conclusions The results show that we can obtain a precise dose calculation for radiotherapy by only to tracking the contribution of primary X-rays and primary scattering X-ray, so, to establishing the database for primary scattering X-ray by Monte Carlo methods is important for fast dose calculation of Monte Carlo method.
出处 《中华放射肿瘤学杂志》 CSCD 北大核心 2012年第4期384-387,共4页 Chinese Journal of Radiation Oncology
基金 黑龙江省自然科学基金资助项目(A200805) 黑龙江省教育厅科技资助项目(11531282)
关键词 散射X线 蒙特卡罗计算方法 剂量学 Scattering of X-ray Monte Carlo calculating method Dosimetry
  • 引文网络
  • 相关文献

参考文献7

  • 1白彦灵,肖雪夫,邵文成.医用加速器8MV X射线在水模体中的一阶散射X射线能谱的蒙特卡罗计算[J].中国医学物理学杂志,2012,29(2):3211-3215. 被引量:4
  • 2Rogers DWO. Monte Carlo techniques in radiotherapy[J].Medical Physics,2002.66-70.
  • 3AAPM task group. Report of AAPM task group NO.105:issues associated with clinical implementation of Monte Carlo-based photon and electron external beam treatment planning[J].Medical Physics,2007.4818-4853.
  • 4Kawrakow I,Fippel M,Friedrich K. 3D electron dose calculation using a Voxel based Monte Carlo algorithm (VMC)[J].Medical Physics,1996.445-457.
  • 5Gardner J,Siebers J,Kawrakow 1. Dose calculation validation of VMC + + for photon beams[J].Medical Physics,2007.1809-1818.
  • 6Cygler JE,Daskalov GM,Chan GH. Evalution of the first commercial Monte Carlo beam treatment planning[J].Medical Physics,2004.142-153.
  • 7Fippel M,Haryanto F,Dohm O. A virtual photon energy fluency model for Monte Carlo dose calculation[J].Medical Physics,2003.301-311.