摘要
用氨水 -EDTA二铵盐作为钨产品的溶剂和干扰抑制剂 ,以空气 -乙炔火焰原子吸收法直接连续测定钨产品中Cd、Co、Cu、Fe、Mg、Mn和Ni元素。经三氧化钨标准样的验证 ,测定值与推荐值相符。实际样品的加标回收率为84.4%~106% ,RSD在1.18 %~5.18
A method for the direct determination of impurity _ elements Cd, Co, Cu, Fe, Mg, Mn and Ni in tungsten products by air-ethyne flame atomic absorption spectrometry has been developed, by using EDTA diammonium salt as solvent and matrix modifier to eliminate interference of matrix and concomitant elements. Standard samples were analyzed with satisfactory results. The recoveries of standard additions and relative standard deviations for practical samples of tungstic oxide and ammonium paratungstate are 84.8%~106% and 1.18%~5.18%, respectively.
出处
《分析测试学报》
CAS
CSCD
2000年第3期27-30,共4页
Journal of Instrumental Analysis
关键词
原子吸收光谱法
钨产品
杂质元素
EDTA二胺盐
Flame atomic absorption spectrometry
Tungsten product
Impurity _ elements
EDTA diammonium salt