期刊文献+

氢气纯度与氢冷发电机的安全运行 被引量:2

The Relations between Hydrogen Purity and the Safe Operation of Hydrogen-cooled Generator
下载PDF
导出
摘要 指出氢气的导热系数最大,为空气的7倍,在同一温度和流速下,放热系数为空气的1.4~1.5倍,作为冷却介质,能有效地将发电机产生的热量传导给冷却器,散发到发电机外,起到冷却发电机的作用。阐述了氢气与空气、氧气混合状态的存在是危险的,在生产氢气过程中一定要保持氢气纯度为99.5%及以上,发电机运行中一定要保持氢气纯度为96%以上,含氧量不超过2%。 The thermal conductivity coefficient of hydrogen is six times higher than that of air. Under the same temperature and flowing speed, the heat transfer coefficient of hydrogen is 1.4-1.5 times as high as that of air. As coolant, it can effectively transfer the heat of generator to condenser, dissipating the heat away from generator and making the generator cooled. The combination of hydrogen and air or oxygen is dangerous, thus, the purity of hydrogen should be maintained above 99.5% during the process of hydrogen production and above 96% while the generator is operating with oxygen content lower than 2%.
作者 王昭武
出处 《山西电力》 2012年第3期64-65,共2页 Shanxi Electric Power
关键词 氢气 纯度 着火 爆炸 hydrogen purity ignition explosion
  • 相关文献

同被引文献6

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部