摘要
以工程实例的形式介绍现浇空心板的平面布置及结构形式。结合空心模壳的抗浮验算、内模安装及抗浮措施,详细地论述了抗偏移的现浇空心板混凝土浇筑施工方案,并对现浇空心模壳局部节点处理提出了一些可行的施工措施。
Based on project examples, the paper introduces the first layout and structure of the cast-in-situ hollow slab, expounds the scheme being under anti-offset cast-in-situ hollow slab concrete construction, including checking computations of hollow shell, inside form board installation and the measures against floating shell,and puts forward some feasible measures to deal with local node of cast-in-situ hollow shell .
出处
《台州学院学报》
2012年第3期40-44,共5页
Journal of Taizhou University
关键词
现浇空心板
空心模壳
抗浮措施
cast-in-situ hollow slab
hollow shell
the measures against floating shell