摘要 目的比较和分析国产、进口第四代人类免疫缺陷病毒(HIV)抗原抗体诊断试剂的特异性及灵敏度。方法用2种第四代HIV诊断试剂分别检测8093份献血者标本和HIV-1 p24抗原国家参考品,并进行分析和评价。结果试剂A的阴性符合率为100%(8085/8085),阳性符合率为100%(8/8),总符合率为100%(8093/8093),试剂B的阴性符合率为99.94%(8080/8085),阳性符合率为100%(8/8),总符合率为99.94%(8088/8093)。结论国产第四代HIV诊断试剂在特异性及灵敏度与进口同类产品具有较高的一致性,可以同时检测HIV1/2抗体和HIV-1 p24抗原,可降低成本。 Objective To compare and analyze the specificity and sensitivity of domestic and foreign Ⅳ generation HIV antigen-antibody diagnostic reagents.Methods Two kinds of Ⅳ generation HIV diagnostic reagents were used to test 8093 specimens of blood donors and HIV-1 p24 antigen national reference materials.Tests were analysed and evaluated.Results Negative consistent rate of reagent A was 100%(8085/8085),positive consistent rate was 100%(8/8),the total consistent rate was 100%(8093/8093).Negative consistent rate of reagent B was 99.94%(8080/8085),positive consistent rate was 100%(8/8),the total consistent rate was 99.94%(8088/8093).Conclusion Domestic and foreign Ⅳgeneration HIV diagnostic reagents are highly similar in specificity and sensitivity.HIV1/2 antibodies and HIV-1 p24 antigen can be detected simultaneously.Costs can be reduced.
机构地区 成都市血液中心
出处 《四川医学》 CAS 2012年第6期1069-1071,共3页 Sichuan Medical Journal
关键词 HIV 诊断 试剂盒 HIV diagnose reagent kit
  • 相关文献

参考文献6

  • 1Joon-Sup Y, Gyo Jun. Evaluation of a new fourth generation en- zyme-linked immunosorbent assay, the LG HIV Ag-Ab Plus, with a combined HIV p24 antigen and anti-HIV-1/2/O screening test [ J ]. Journal of Virological Methods, 2006,137(2) :292 -297.
  • 2Said Aboud, Willy Urassa. Evaluation of HIV antibody and antigen/ antibody combination ELISAs for use in an ahemative confirmatory HIV testing strategy in Dar es Salaam, Tanzania[ J]. Journal of Viro- logical Method, 2006,135 (2) : 192 - 196.
  • 3Weber B, Fall EMB. Reduction of the diagnostic window by new foruth-generation human immunodeficicncy virus screening assays [ J ]. Journal of Clinical Microbiology, 1998,36 (8) :2235 - 2239.
  • 4Jingzhi Pan, Jianmin Chert. Detection of very early antibody to native HIV antigens by HIV neutralization and live-cell immunofluorescence assays [ J ]. Antiviral Research, 2006,70 ( 2 ) : 21 - 27.
  • 5Stefan Brust, Hedwig Duttmann. Shtorting of the diagnostic window with a new combined HIV p24 antigen and anti-HIV-1/2/O screeningtest[ J]. Virological Methods ,2000,90(2) :153 - 165.
  • 6朱绍汶,陈妍.两家国产4代HIV试剂特异性评价[J].临床输血与检验,2010,2(4):347-348. 被引量:2

共引文献1

同被引文献40

  • 1Sun Z, Ming L, Zhu X, et al. Prevention and control of hepatitis B in China. Med Virol, 2002,67(3) :447.
  • 2Tosti ME,Prati D,Manca M,et al. An estimate of the current risk of transmitting blood-borne infections through blood transfusion in Italy. British J Haematol,2002,117 ( 1 ) :215-219.
  • 3Strainer SL, Notari EP, Krysztof DE, et al. Hepatitis B virus testing by minipool nucleic acid testing: does it improve blood safety? Transfusion, 2013, doi : 10. 1111/trf. 12213.
  • 4Ortiz MR. HIV, AIDS and aexuality[J]. Nurs Clin Noah Am,2007,42(4):639-653.
  • 5Sun Z, Ming L, Zhu X,et al. Prevention and control of hepatitis B in China. bled Virol,2002,67(3) : 447.
  • 6Tosti ME,Prati D,Manca M,et al. An estimate of the eurrent risk of transmitting blood-borne infections through blood transfusion in Italy. British J Haematol,2002,117( 1 ) :215-219.
  • 7Stramer SL, Notari EP, Kryszt DE, et al. Hepatitis B virus testing by minipool nucleic acid testing: does it improve blood safety? Transfusion, 2013, doi: 10.1111/trf. 12213.
  • 8胡燕,侯俊,冯燕青,冯长访,史素娟,沈宏辉,王志杰,王保君,貌盼勇.HIV-1/2抗体和P24抗原联合检测试剂盒的研制与评价[J].中华实验和临床病毒学杂志,2007,21(4):391-393. 被引量:4
  • 9杨育红,陈杰毅,陈明春,刘建忠,吴幼玲.泉州市318例HIV抗体筛查阳性的确认结果分析[J].实验与检验医学,2010,28(1):37-38. 被引量:13
  • 10朱绍汶,陈妍.两家国产4代HIV试剂特异性评价[J].临床输血与检验,2010,2(4):347-348. 被引量:2