期刊文献+

内蒙古中部地区地源热泵单位井深换热量设计的研究 被引量:5

Designing of Average Quantity of Heat Per Meter for Ground Source Heat Pump at Central Inner Mongolia
下载PDF
导出
摘要 由于地源热泵系统具有明显的地域性特点,且各地区气候地质差异较大,其设计计算不具有普遍性。通过对呼和浩特某工程地下岩土结构的实测数据的分析,重点对比了不同单位井深换热量。模拟不同条件下,地埋管换热器周围土壤的温度变化。研究不同取热量对热泵系统运行稳定的影响,以期为呼和浩特及周边地区的地源热泵的应用设计提供依据。 Ground source heat pump system is obvious in regional characteristics with larger differences of the regional geological fea- tures. Its design and calculation are not universal. Through analysis on an under-ground geological structure of the measured data in Hohhot, various overage quantities of heat per meter are compared. Different conditions are simulated, including the temperature variation of the sur- rounding soil of the ground heat exchanger. The influence of different heat on heat pump system stable running is studied, in order to provide a basis to ground source heat pump applications designed for ttohhot and the surrounding areas.
作者 张永志 顾洁
机构地区 内蒙古科技大学
出处 《建筑节能》 CAS 2012年第6期24-25,32,共3页 BUILDING ENERGY EFFICIENCY
关键词 地源热泵 单位井深换热量 土壤温度 ground source heat pump average quantity of heat per meter soil temperature
  • 相关文献

参考文献3

二级参考文献4

  • 1CHIASSON A D, CENK YAVUZTURK P E. Assessment of the viability of hybrid geothermal heat pump system with solar thermal collector [C]∥ ASHRAE Trans: Symp KC-03-3-3:487-499.
  • 2CANE R L D, ENG P, FORGAS D A. Modeling of ground source heat pump performance [J]. ASHRAE Trans, 1991, 97(1): 909-925.
  • 3李家伟. 对土壤热泵装置的研究[D]. 青岛:青岛建筑工程学院,1995.LI Jia-wei. Study on the installation of ground source heat pump [D]. Qingdao: Qingdao Inst. of Architecture and Eng., 1995. (in Chinese)
  • 4李元旦,张旭,周亚素,陈沛霖.土壤源热泵冬季工况启动特性的实验研究[J].暖通空调,2001,31(1):17-20. 被引量:48

共引文献48

同被引文献43

引证文献5

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部