摘要
介绍广州国际体育演艺中心电气设计的难点:①变压器平时负荷率很低,空载损耗大;②金属卤化物灯熄灭后重启时间长;③比赛大厅火灾探测器的选择。提出解决办法。
Some difficulties found during the electrical design for Guangzhou International Sports Arena are introduced and corresponding solutions are offered in this paper: (1) as the load rate is very low usually, the no-load loss of transformer is high; (2) the metal halide lamp needs a long time to restart after turning off; (3) the choice for fire detector in competition hall.
出处
《建筑电气》
2012年第6期60-63,共4页
Building Electricity
关键词
变配电系统
变压器负荷率
场地照明
金属卤化物灯
火灾自动报警系统
空气采样
早期烟雾探测报警系统
Transformation and distribution system Load rate of transformer Field lighting Metal halide lamp Automatic fire alarm system Air sampling early smoke detection alarm system