水电站机电设备正常运行期间基本没有污染物排放,但在发生事故等特殊情况下,仍存在污染物不正常排放的可能。尤其是含油污水,若不能得到有效处理就直接排放到下游河道,将造成河道污染。文章对水电站机电设备运行中的含油污水的来源、特点、性质及处理方法进行了分析,并对越南安科水电站含油污水处理系统设计进行了介绍。
There is nearly no pollutant emission during normal operation of electromechanical equipment in hy- charged to the river directly without effective treatment. The paper makes an analysis on the resource, character- istics, performance and treatment methods of the oily sewage from abnormal operation of electromechanical e- quipment. Meantime, it also makes an introduction to the Khe-kanak hydropower station. design of oily sewage treatment system for Vietnam An
出处
《红水河》
2012年第3期12-16,37,共6页
Hongshui River
关键词
水电站
机电设备
含油污水处理
系统设计
hydropower station
eletromechanical equipment
oily sewage treatment
system design