采用ISO 9705标准全尺寸单室火灾实验方法,对3种常用的饰面装饰材料的单室火灾进行实验研究,实时测量地面辐射强度、室内和开口部位不同高度的温度随火灾变化的情况,分析装修材料对室内火灾的影响,测算轰燃时间以及冷热气层界面位置的变化,为火灾预防和扑救提供参考。
In this study, the ISO-9705 room was used to investi- gate the enclosure fire decorated with three traditional lining materials. The flame radiant intensity at the floor center, and the temperature distributions at the corner of enclosure and doorway at different heights were measured. The influences of decoration materials on the enclosure fire development were studied. The flashover time and the varied positions of the in- terface layer between the hot air layer and the cold air layer were evaluated to provide the experimental data for references of relevant fire prevention and fire fighting.
出处
《消防科学与技术》
CAS
北大核心
2012年第7期684-687,共4页
Fire Science and Technology
关键词
饰面材料
火灾
轰燃
冷热气分界面
ISO 9705 room
fire
flashover
cold-hot air inter-face layer