期刊文献+

电厂凝汽器不锈钢管的耐蚀性及选材试验 被引量:3

Corrosion Resistance of Stainless Steel Condensor in Power Plant and Materials Selection
下载PDF
导出
摘要 用电化学方法对电厂凝汽器工况条件下 3 0 4、3 16L、3 17L 不锈钢管的耐蚀性能作了对比研究 ,针对电厂用冷却水质进行了初步选材试验 ,并与 H Sn70 -1A黄铜管、BFe3 0 -1-1白铜管作了比较。结果表明 :不锈钢管的耐蚀性能比铜管好得多 ;不同品牌不锈钢的耐蚀性差异较大 ,应用时应根据水质工况合理选材 。 The corrosion resistance of stainless steel, brass and cupronickel in cooling water for power plant was studied by electrochemical methods. It was shown that the corrosion resistance of stainless steel was much better than copper alloys, but the corrosion resistance was quite different among different kinds of stainless steels. The materials selection should be in consideration of industrial water conditions.
出处 《材料保护》 CAS CSCD 北大核心 2000年第4期36-38,共3页 Materials Protection
  • 相关文献

参考文献5

  • 1杨武 顾睿祥.金属的局部腐蚀[M].北京:化学工业出版社,1995.75-84.
  • 2杨武,金属的局部腐蚀,1995年
  • 3周国定.交流阻抗法在电力设备腐蚀研究中的应用[J].中国电力,1994,27(10):24-29. 被引量:12
  • 4Zhou Guoding,Bulletin Electrochemistry,1991年,2期,60页
  • 5(SD 116 84)火力发电厂凝汽管选材导则,1984年

共引文献70

同被引文献12

引证文献3

二级引证文献9