摘要 High performance size exclusion chromatography (HPSEC) is used in water quality research primarily to determine the molecular weight distribution of the dissolved organic matter (DOM), but by applying peak fitting to the chromatogram, this technique can also be used as a tool to model and predict DOM removal. Six low specific UV absorbance (SUVA) source waters were treated using coagulation with alum and both the source and treated water samples were analysed using HPSEC. By comparing the molecular weight profiles of the source and treated waters, it was established that several DOM components were not effectively removed by alum coagulation even after high dosage alum treatment. A peak-fitting technique was applied based on the concept of linking the character (molecular weight profile) of the recalcitrant organics in the treated water with those of the source water. This was then applied to predict DOM treatability by determining the areas of the peaks which were assigned to removable organics from the source water molecular weight profile after peak fitting, and this technique quantified the removable and non-removable organics. The prediction was compared with the actual dissolved organic carbon (DOC) removal determined from jar testing and showed good agreement, with variance between 2% and 10%. This confirmed that this prediction approach, which was originally developed for high SUVA waters, can also be applied successfully to predict DOC removal in low SUVA waters. High performance size exclusion chromatography (HPSEC) is used in water quality research primarily to determine the molecular weight distribution of the dissolved organic matter (DOM), but by applying peak fitting to the chromatogram, this technique can also be used as a tool to model and predict DOM removal. Six low specific UV absorbance (SUVA) source waters were treated using coagulation with alum and both the source and treated water samples were analysed using HPSEC. By comparing the molecular weight profiles of the source and treated waters, it was established that several DOM components were not effectively removed by alum coagulation even after high dosage alum treatment. A peak-fitting technique was applied based on the concept of linking the character (molecular weight profile) of the recalcitrant organics in the treated water with those of the source water. This was then applied to predict DOM treatability by determining the areas of the peaks which were assigned to removable organics from the source water molecular weight profile after peak fitting, and this technique quantified the removable and non-removable organics. The prediction was compared with the actual dissolved organic carbon (DOC) removal determined from jar testing and showed good agreement, with variance between 2% and 10%. This confirmed that this prediction approach, which was originally developed for high SUVA waters, can also be applied successfully to predict DOC removal in low SUVA waters.
出处 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2012年第7期1174-1180,共7页 环境科学学报(英文版)
基金 supported by the National Natural Science Foundation of China (No. 51025830) the National Basic Research Program of (973) China (No.2011CB933700) the South Australian Premier’s Science and Research Fund Project "Development of materials engineering solutions for treatment of Murray-Darling Basin sourced water supplies" supported by the special fund from the State Key Laboratory of Environmental Aquatic Chemistry, Project 08K08ESPCR
关键词 DOM high performance size exclusion chromatography peak fitting water treatment DOM high performance size exclusion chromatography peak fitting water treatment
  • 相关文献

参考文献20

  • 1Allpike B P, Heitz A, Joll C A, Kagi R I, Abbt- Braun G, Frimmel F H et al., 2005. Size exclusion chromatography to characterize DOC removal in drinking water treatment. Environmental Science and Technology, 39(7): 2334-2342.
  • 2Andersen D O, Alberts J J, Takaics M, 2000. Nature of natural or- ganic matter (NOM) in acidified and limed surface waters. Water Research, 34(1): 266-278.
  • 3Bolto B, Abbt-Braun G, Dixon D, Eldridge R, Frimmel F, Hesse Set al., 1999. Experimental evaluation of cationic polyelectrolytes for removing natural organic matter from water. Water Science and Technology, 40(9): 71-79.
  • 4Chow C W K, Fabris R, van Leeuwen J A, Wang D S, Drikas M, 2008. Assessing natural organic matter treatability using high performance size exclusion chromatography. Environ- mental Science and Technology, 42(17): 6683~6689.
  • 5Chow C W K, van Leeuwen J A, Drikas M, Fabris R, Spark K M, Page D W, 1999. The impact of the character of natural organic matter in conventional treatment with alum. Water Science and Technology, 40(9): 97-104.
  • 6Chow C W K, van Leeuwen J A, Fabris R, Drikas M, 2009. Optimised coagulation using aluminium sulfate for the removal of dissolved organic carbon. Desalination, 245(1- 3): 120-134.
  • 7Del Vecchio R, Blough N V, 2004. On the origin of the optical properties of humic substances. Environmental Science and Technology, 38(14): 3885-3891.
  • 8Gjessing E T, Egeberg P K, Hakedal J, 1999. Natural organ- ic matter in drinking water--The "NOM-typing project", background and basic characteristics of original water sam- pies and NOM isolates. Environment International, 25(2-3): 145-159.
  • 9Korth A, Fiebiger C, Bornmann K, Schmidt W, 2004. NOM increase in drinking water reservoirs- relevance for drinking water production. Water Science and Technology: Water Supply, 4(4): 55-60.
  • 10Lankes U, Ltidemann H D, Frimmel F H, 2008. Search for basic relationships between "molecular size" and "chemical structure" of aquatic natural organic matter - Answers from 13C and 15N CPMAS NMR spectroscopy. Water Research, 42(4-5): 1051-1060.

同被引文献19

引证文献4

二级引证文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部