摘要 本文将自制聚偏氟乙烯(PVDF)膜与市场商品膜比较,测定了膜的纯水通量和截留率,并将其应用于卫生纸厂和文化纸厂废水处理。试验发现:在室温、及压力为0.2MPa的条件下,自制PVDF膜的纯水通量为54 L/(m2.h),相对于分子量为20000的葡聚糖20的截留率为89.52%;通过测定两种废水过滤后的三项指标(COD、BOD5、SS)发现,自制膜处理效果相对较好。 This paper compared a self-prepared poly (vinylidene fluoride) (PVDF) membrane with the commercial products, hy measurement of pure water flux and retention rate. And all these membranes were applied to wastewater treatment of tissue and eultural paper mills. The results showed that the pure water flux of the self-pre- pared PVDF membrane was 54 L/(m^2 oh) , and the retention rate was 89.52% , related to the dextran 20 with a molecular weight of 20 000, under the conditions of room temperature and pressure of 0.2MPa. By determination of COD, BOD5 and SS of the filtrates of these two wastewater, it was found that the self-prepared membrane had a better treatment effect.
出处 《造纸科学与技术》 北大核心 2012年第3期93-96,共4页 Paper Science & Technology
基金 广东省科技计划项目(2010B010800044)
关键词 PVDF膜 造纸废水 BOD5 COD SS PVDF membrane papermaking wastewater BOD5 COD SS
  • 相关文献

参考文献9

二级参考文献11

  • 1吕晓龙.超滤膜孔径及其分布的测定方法──Ⅰ.常用测定方法讨论[J].水处理技术,1995,21(3):137-141. 被引量:28
  • 2刘昌盛 邬行彦 等.膜的污染与清洗[J].膜科学与技术,1996,16(6):25-30.
  • 3陈淑桃 葛尚乾 等.碱法制浆化学药品的回收[M].北京:轻工业出版社,1991.10-15.
  • 4刘昌盛,膜科学与技术,1996年,16卷,6期,25页
  • 5蒋其昌,造纸工业环境保护概论,1992年,181页
  • 6陈淑桃,碱法制浆化学药品的回收,1991年,10页
  • 7中华人民共和国海洋行业标准HY/T050—1999.中空纤维超滤膜测试方法[S].[S].北京,1999..
  • 8ASTM designation E 1343 - 90 ( Reapproved 2001 ) Stan-ard test method for molecular weight cutoff evaluation of flat sheet uhrafiltration membranes[S].
  • 9Bottino A, Capannelli G A. Effect of operation conditions on the performance on the membrane[J]. J Membr Sci,1984,21 : 247 - 267.
  • 10Mulder M. Basic principles of membrane technology[M].Kluwer Academic Publishers, 1991. 131-133.

共引文献76

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部