摘要
针对制氢转化炉管系 (包括转化管、集气管、猪尾管 )在制造安装过程中出现焊接裂纹的原因进行了分析 。
In the light of hydrogen manufacturing coverted furnace tube system(including conversion tube,gas gathering tube and pigtail tube)occuring weld fissure during manufacture and installation,the reason of fissure is analized.The repair plan and specific repair measures are recommended.
出处
《石油化工设备技术》
CAS
2000年第2期15-19,27,共6页
Petrochemical Equipment Technology
关键词
制氢
转化炉
转化管
焊接裂纹
维修
Hydrogen manufacturing converted furnace,Conversion tube,Gas gathering tube,Welding fissure,Reason analysis,Repair on site