摘要
空气压缩机二级缸及排气管道的存压造成其零部件严重损坏,影响了热媒炉的安全运行。通过分析故障原因,提出了改进措施,即在空压机上安装一套放气泄压系统,可有效解决二级缸及排气管道存压的问题,实际运行工况表明,安装泄压系统后的空压机故障停机次数大幅度降低,延长了设备的使用寿命,保证了热媒炉的安全运行。
In the light of the standing pressure within the secondary cylinder of air compressor and air-supply pipe,it influences the safe operation of heat medium heater,an air relief system to eliminate the standing pressure has been adopted in the air-supply system. Actual operation of the system has shown that the shutdown frequency of air compressor has been greatly reduced,which is significantly beneficial to the heat medium heater.
出处
《油气储运》
CAS
北大核心
2000年第6期48-49,共2页
Oil & Gas Storage and Transportation
关键词
空气压缩机
排气管道
加热炉
安全
炼油
air compressor,standing pressure,trouble shooting,air relief system