摘要 目的比较钛板固定系统在胸骨横断切口中与传统钢丝固定的区别。方法对2005年1月至2009年12月期间收治的249例胸骨横断切口行胸腺和胸腺瘤切除的重症肌无力患者进行回顾性分析,其中钢丝缝合胸骨120例(钢丝组),应用钛板固定系统129例(钛板组),并比较两组患者的胸骨愈合情况。结果术后短期(1周内):(1)钛板组患者的胸骨稳定性明显优于钢丝组(P<0.01);(2)钛板组患者术后疼痛评分平均为3.79±1.31,低于钢丝组的4.48±1.43(P<0.01);(3)钛板组患者平均下床活动时间为(2.78±0.79)天,早于钢丝组的(3.59±0.89)天(P<0.01);(4)两组间的表面伤口延期愈合无明显差异(P>0.05)。术后长期(6周以上):钛板组的胸骨愈合率优于钢丝组(P<0.05)。结论钛板固定系统对胸骨断端的固定呈高强度三维固定。在胸骨横断的手术患者中使用钛板固定系统能有效提高术后患者的胸骨稳定性,减轻患者术后疼痛,增强患者活动能力,降低远期胸骨不愈发生率,较传统钢丝固定有明显优势。 Objective To compare the difference between titanium plate fixation system and steel wire fixation in sternum transverse incisions.Methods Sternal healing status was reviewed in 249 patients with myasthenia gravis that underwent thymectomy or excision of thymoma from Jan.2005 to Dec.2009.Sternum transverse incision was adopted in all these patients.One hundred and twenty patients received steel wire fixation of the sternum,and the rest applied titanium plate fixation.A comparison of sternal healing status was made between the two groups.Results Short-term(within 1 week after surgery) results:(1) The stability of the sternum in the titanium plate group was significantly superior to that in the steel wire group(P0.01);(2) The average pain score in the titanium plate group(3.79±1.31) was obviously lower than that in the steel wire group(4.48±1.43,P0.01);(3) The average out-of-bed time after surgery in the titanium plate group(2.78±0.79 days) was earlier than that in the steel wire group(3.59±0.89 days,P0.01);(4) There was no significant difference in delayed wound healing between the two groups(P0.05).Long-term(6 weeks after surgery or longer) result: The sternal healing rate in the titanium plate group was significantly higher than that in the steel wire group(P0.05).Conclusions Biomechanically,the titanium plate fixation system could provide high intensity three diamensional fixation.In patients who underwent sternum transverse incisions for thymectomy and/or excision of thymoma,the introduction of titanium plate fixation system can effectively improve the postoperative sternal stability,relieve postoperative pain,enhance the patient's physical activity and decrease the long-term nonunion rate of the sternum.Therefore,it has significant advantages over the conventional method of steel wire fixation.
出处 《复旦学报(医学版)》 CAS CSCD 北大核心 2012年第4期400-404,共5页 Fudan University Journal of Medical Sciences
关键词 重症肌无力 胸骨横断 钛板 三维固定 胸骨不愈 myasthenia gravis sternum transverse incision titanium plate three dimensional fixation sternal nonunion
  • 相关文献

参考文献16

  • 1Sarr MG, Gott VL, Townsend TR. Mediastinal infection after cardiac surgery[J]. Ann Thorac Surg, 1984, 38 (4) :415 - 423.
  • 2Grossi EA,Culliford AT, Krieger KH, etal. A survey of 77 major infectious complications of median sternotomy: a review of 7,949 consecutive operative procedures[J]. Ann ThoracSurg, 1985, 40(3) :214-223.
  • 3Borger MA, Rao V, Weisel RD, et al. Deep sternal wound infection: risk factors and outcomes [J]. Ann Thorac Surg, 1998, 65(4) :1050- 1056.
  • 4LuJC,GraysonAD, JhaP, etal. Risk factors for sternal wound infection and mid-term survival following coronary artery bypass surgery [J].Eur J Cardiothorac Surg, 2003, 23(6) : 943 - 949.
  • 5Loop FD,Lytle BW, Cosgrove DM, et al. Sternal wound complications after isolated coronary artery bypass grafting: early and late mortality, morbidity, and cost of care[J]. Ann Thorac Surg, 1990, 49(2) :179 - 186.
  • 6ZeitaniJ, Bertoldo F, Bassano C, et al. Superficial wound dehiscence after median sternotomy: surgical treatment versus secondary wound healing [J]. Ann Thorac Surg, 2004, 77(2) :672- 675.
  • 7Ozaki W, Buchman SR, Iannettoni MD, et al. Biomechanical study of sternal closure using rigid fixation techniques in human cadavers[J].Ann Thorac Surg, 1998,65(6) :1660 - 1665.
  • 8Cohen DJ, Griffin LV. A biomechanical comparison of three sternotomy closure techniques [J]. Ann Thorac Surg , 2002, 73(2) :563 - 568.
  • 9Mitra A,Elahi MM, Tariq GB, et al. Composite plate and wire fixation for complicated sternal closure[J]. Ann Plast Surg, 2004, 53(3) :217- 221.
  • 10Song DH, Agarwal JP, Jeevanandam V. Rigid sternal fixation in the cardiac transplant popnlation[J]. J Thorac Cardiovasc Surg, 2003, 126(3) :896 - 897.

二级参考文献6

  • 1Brookes J G, Dunn R J, Rogers I R. Sternal fractures: a retrospective analysis of 272 case[J]. J Trauma, 1993,35(1): 46-54.
  • 2Kehdy F, Richardson J D. The utility of 3-D CT scan in the diagnosis and evaluation of sternal fractures[J]. J Trauma, 2006, 60(3):635- 636.
  • 3Wiener Y, Achildiev B, Karni T, et al. Echocardiogram in sternal fracture[J]. Am J Emerg Med,2001,19(5):403-405.
  • 4Engin G, Yekeler E, Guloglu R, et al. US versus conventional radiography in the diagnosis of sternal fractures[J], Acta Radioi, 2000,41(3):296-299.
  • 5Kao C L, Chang J P, Chang C H. Acute mediastinal tamponade secondary to blunt sternal fracture[J]. J Trauma, 2000,48(1): 157 -158.
  • 6Bonney S, Lenczner E, Harvey E J. Sternal fractures: anterior plating rationale[J]. J Trauma, 2004,57 (6) : 1344- 1346.

共引文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部