期刊文献+

骶骨骨折后路横置钢板固定的影像解剖学研究 被引量:1

The dorsal transverse reconstruction plate fixation for treating sacral fractures:applied anatomy
下载PDF
导出
摘要 目的研究后路横置钢板固定骶骨骨折的可行性。方法临床采集60例成人正常骨盆CT数据(男30例,女30例),导入Mimics14.1行三维重建,用MedCAD模拟置钉,观测螺钉位置及毗邻,确定S1~4进钉点。测量钉道长度及其与水平面、冠状面及矢状面的夹角。解剖30侧成人尸体标本,观察进钉点毗邻。2具成人骨盆标本模拟置钉,经X线验证试验结果。结果男性内侧钉道长度S1为(32.78±2.10)mm、S2为(28.54±2.67)mm、S3为(18.54±1.86)mm、S4为(12.58±1.18)mm;女性内侧钉道长度S1为(31.18±2.52)mm、S2为(26.00±2.49)mm、S3为(16.79±2.09)mm、S4为(11.19±1.53)mm;男性外侧钉道长度S1为(35.78±1.88)mm、S2为(29.99±2.48)mm、S3为(22.53±2.21)mm、S4为(13.62±1.58)mm;女性外侧钉道长度S1为(33.03±2.23)mm、S2为(29.34±3.87)mm、S3为(21.00±2.12)mm、S4为(12.72±1.83)mm;验证结果满意。结论后路横置钢板可固定骶骨纵形或斜行骨折,从形态学上具有可行性。 ObjeOive To study the feasibility of the dorsal transverse reconstruction plate fixation for treating longitudinal or oblique sacral fractures. Methods CT data of pelvis were collected from 60 healthy adults (30 males and 30 females)and then imported into Mimicsl4.1 for 3D image reconstruction. MedCAD was used to simulate screw placement. Observation was made on the screw position, adjacent vessels and nerves for determining the S1-4 screw entry points. The length of screw trajectory was measured, as well the intersection angle between the screw trajectory and horizontal plane, coronal plane and sagittal plane, respectively. 30 cadaveric specimens were dissected to observe the distribution of the vessels and nerves around the screw entry points. Simulated screw placements were performed on 2 adult pelvic specimens, with the results testing by X-ray. Results The length of medial screw trajectory in males was (32.78±2.10)mm for Sl, (28.54±2.67)mm for S2, (18.54±1.86)mm for $3, and (12.58±1.18)mm for S4; that in females was(31.18±2.52) mm, (26.00±2.49)mm, (16.79±2.09)mm, and (11.19±1.53)mm respectively. The length of lateral screw trajectory in males was (35.78±1.88)mm for $1, (29.99±2.48)mm for $2, (22.53±2.21)mm for $3 and (13.62± 1.58)ram for $4; that in females was (33.03±2.23)mm, (29.3±3.87)mm, (21.00±2.12)mm, and (12.72±1.83)mm respectively. The test results proved satisfactory. Conclusions The dorsal transverse reconstruction plate is capable of fixing longitudinal or oblique sacral fracture with small trauma, satisfactory reduction and marked sturdiness.
出处 《中国临床解剖学杂志》 CSCD 北大核心 2012年第4期398-403,共6页 Chinese Journal of Clinical Anatomy
关键词 骶骨 骨折 螺钉 内固定 解剖学 Sacrum Fracture Screws Fixation Anatomy
  • 相关文献

参考文献11

  • 1Taguchi T,Kawai S,Kaneko K,et al. Operative management of displaced fractures of the sacrum[J].J Orthop Sci, 1999, 4(5):347-352.
  • 2Oransky M,Gasparini G. Associated lumbosacral junction injuries (LSJIs) in pelvic fractures[J].J Orthop Trauma,1997, 11 (7):509-512.
  • 3Ayoub MA. Vertically unstable sacral fractures with neurological insult: outcomes of surgical decompression and reconstruction plate internal fixation[J].IntOrthop,2009,33(1):261-267.
  • 4Totterman A,Glott T,Soberg HL, et al. Pelvic trauma with displaced sacral fractures: functional outcome at one year [J]. Spine,2007,32(13): 1437-1443.
  • 5Bellabarba C,Schildhauer TA,Vaccaro AR,et al. Complications associated witsurgical stabilization of high-grade sacral fracture dislocations with spino-pelvic instability[J].Spine,2006,31 (11 suppl):S80-S88.
  • 6Reilly MC,Zinar DM,Matta JM.Neurologic injuries in pelvic ring fractures [J].Clin Orthop Relat Res,1996,329:28-36.
  • 7Zindrick MR,Wiltse LL,Widell EH,et al.A biomechanical study of intrapeduneular screw fixation in the lumbosacral spine [J].Clin Orthop Relat cRes,1986, 203:99-112.
  • 8Mirkovic S, Abitbol JJ , Steinman J, et al. Anatomic consideration for sacral screw placement [J].Spine, 1991 , 16 (6 suppl) :289-294.
  • 9孙贺,徐达传,陈铭锐,向宇燕,仇恒志,王胜林.经后路第2骶椎螺钉进钉方法的应用解剖[J].中国临床解剖学杂志,2002,20(3):181-183. 被引量:18
  • 10王奇,黄其杉,王向阳,胡月正,郑昌坤,郑立诚,窦海成.骶骨后路钉板固定的解剖学研究[J].中华骨科杂志,2010,30(3):277-281. 被引量:14

二级参考文献26

  • 1姚家庆,戴蘅茹,鄧道钧.国人成年男子髂内、外动脉分支的观察[J].解剖学报,1965(3):356-373. 被引量:3
  • 2章中春,蔡德亨.髂内动脉的分支类型[J].解剖学报,1964(4):447-457. 被引量:2
  • 3钟世镇,刘正津.髂内动脉及其主要分支的观察[J].解剖学报,1964(2):173-180. 被引量:13
  • 4路青林,刘庆胜,李树锋,韩建波,陈猛.骶骨骨折合并神经损伤的治疗[J].中华创伤骨科杂志,2005,7(1):91-92. 被引量:16
  • 5Fountain SS, Hamilton RD, Jameson RM. Transverse fractures of the sacrum: a report of six cases. J Bone Joint Surg (Am), 1977, 59(4): 486-489.
  • 6Denis F, Davis S, Comfort T. Sacral fractures: an important problem. Retrospective analysis of 236 eases. Clin Orthup Relat Res, 1988(227): 67-81.
  • 7Gibbons KJ, Soloniuk DS, Razack N. Neurological injury and patterns of sacral fractures. J Neurosurg, 1990, 72(6): 889-893.
  • 8Kim MY, Reidy DP, Nolan PC, et al. Transverse sacral fractures: case series and literature review. Can J Surg, 2001, 44(5): 359-363.
  • 9Roy-Camille R, Saillant G, Gagna G, et al. Transverse fracture of the upper sacrum. Suicidal jumper's fracture. Spine (Phila Pa 1976), 1985, 10(9): 838-845.
  • 10Schmidek HH, Smith DA, Kristiansen TK. Sacral fractures. Neurosurgery, 1984, 15(5): 735-746.

共引文献38

同被引文献10

引证文献1

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部