期刊文献+

连体位置及刚度变化对双塔楼地震响应的影响 被引量:1

Influence of gallery position and rigidity variation on seismic response of connected tall building of twin tower
下载PDF
导出
摘要 双塔楼连体结构中的连接体使得原来彼此独立的单体变成了整体,结构的动力特性和抗震性能发生了很大变化。文章建立一对称双塔楼连体结构的空间模型,然后通过变化连体的位置和刚度,并用有限元分析软件SAP2000进行地震反应的线性时程分析,研究连体对结构的基本自振周期、顶层位移、基底剪力的影响,最后比较分析结果得出连体最优的位置及刚度。 The gallery in the connected tall building of twin tower makes the separated buildings become one. Consequently the dynamic characteristics and earthquake resistant behavior of the structure change a lot. A 3D model of symmetrical structure of connected tall building of twin tower is set up in this paper, and a linear time-history seismic analysis of the frame is made by changing the gallery position and rigidity with the finite element analysis software SAP2000. The best position and rigidity of the gallery are found out through the analysis of the influence of the gallery on the frame's basic natural period of vibration, top displacement and bottom shear force.
作者 汪莉 盛宏玉
出处 《合肥工业大学学报(自然科学版)》 CAS CSCD 北大核心 2012年第7期938-941,共4页 Journal of Hefei University of Technology:Natural Science
基金 国家自然科学基金资助项目(51178156)
关键词 双塔楼连体结构 连体位置 连体刚度 线性时程分析 SAP2000软件 structure of connected tall building of twin tower gallery position gallery rigidity linear time-history analysis SAP2000 software
  • 相关文献

参考文献7

二级参考文献20

  • 1邹汇源.高层建筑结构转换层施工技术[J].山西建筑,2005,31(13):95-96. 被引量:4
  • 2陈幼平,周宏业.斜拉桥地震破坏的计算研究[J].地震工程与工程振动,1995,15(3):127-134. 被引量:18
  • 3包世华,王建东.大底盘多塔楼连体结构的受力分析[J].建筑结构,1996,26(11):7-13. 被引量:20
  • 4王亚勇,戴国莹,罗开海,等.GB 50011-2008建筑抗震设计规范[S].北京:中国建筑工业出版社,2008.
  • 5徐培福,黄小坤,容柏生,等.JGJ 3-2002高层建筑混凝土结构技术规程[S].北京:中国建筑工业出版社,2002.
  • 6GB50011-2001.建筑抗震设计规范[S].[S].,..
  • 7GBS0011-2001.建筑抗震设计规范[S].[S].,..
  • 8日本建筑学会.刘文光译.2006.隔震结构设计[M].北京:地震出版社.
  • 9JGJ 3-2002,高层混凝土结构技术规程[S].
  • 10陈岱林,李云贵,魏文朗.多层及高层结构CAD软件高级应用[M].北京:中国建筑工业出版社,2006.

共引文献12