期刊文献+

2011年湖南省肿瘤标志物项目检测室间质量评价 被引量:2

Analysis of External Quality Assessment Results of Tumor Markers Detection in Hunan Province in 2011
原文传递
导出
摘要 目的讨论影响肿瘤标志物(tumor markers,TM)项目检测室间质量评价(EQA)结果准确性的影响因素。方法对2011年TM项目检测的EQA回报数据进行统计分析。结果 2011年TM项目EQA参评实验室合格率为74.3%;各项目检测试剂分组数据和方法学分组数据平均CV值均值大部分高于NACB的最新指南建议值(批间CV<10%)。经无重复双因素方差分析,不同方法分组各项目统计结果合格率及CV值的组间差异有统计学意义(P<0.05),不同试剂分组的CV值差异亦有统计学意义(P<0.05)。结论本省TM EQA参评实验室过少,EQA样本的靶值代表性待提高;实验室选择的检测系统不一致是TM项目EQA的检测结果的及格率和PT得分不理想的原因;分组测定EQA结果以电化学发光组准确度最好,试剂分组以进口试剂EQA结果精密度较好。 Objective To assess the analytical performances of the laboratories in Hunan Province by evaluating the accuracy of external quality assessment(EQA) results of tumor markers(TMs) detection and explore the influencing factors.Methods EQA data of tumor markers reported from various participant laboratories in Hunan Province in 2011 were statistically analyzed.Results In 2011,the qualified rate of TMs EQA in participant laboratories was 74.3%.The average CVs of TMs EQA results when grouped by detection reagents or by methodology were higher than the suggested values in the latest guide of NACB(inter-run CV10%).Grouped by methodology,the qualified rates and CV values of all TMs items were significantly different(P0.05),so were the CV values of TMs when grouped by detection reagents.Conclusions The laboratories that participated in TMs EQA in Hunan Provicne in 2011 are few.The representativeness of target values of EQA samples waits for being improved.Inconsistent detection systems in various laboratories may be the main reason for the non-ideal pass rate and proficiency testing(PT) scores.The accuracy of electrochemiluminescence method is the best.The precision of imported reagents is better than domestic ones.
出处 《实用预防医学》 CAS 2012年第7期1073-1074,共2页 Practical Preventive Medicine
关键词 肿瘤标志物(TM) 室间质量评价(EQA) 湖南 Tumor markers External quality assessment Hunan province
  • 相关文献

参考文献8

  • 1Meany DL, Sokoll LJ, Chan DW. Early detection of cancer: immunoas- says, for plasma tumor markers [ J ]. Expert Opin Med Diagn, 2009,3 (6) :597 - 605.
  • 2张建平,王治国.临床检验室间质量评价计划主要问题以及研究进展[J].中华检验医学杂志,2007,30(9):977-981. 被引量:33
  • 3Sturgeon CM, Duffy MJ, Stenman UH, et al. National academy of clinical biochemistry laboratory medicine practice guidelines for use of tumor markers in testicular, prostate, coloreetal, breast, and ovari an cancers[J]. Clin Chem, 2008, 54(12) :e11 -79.
  • 4Zucchelli GC, Pilo A, Chiesa MR, et al. Minimizing between - kit variability in immunoassay for carcinoembryonic antigen by use of a common standard[J] : Clin Chem, 1986, 32(10):1942- 1943.
  • 5Slev PR, La' ulu SL, Roberts WL. Intermethod differences in results for total PSA, free PSA, and percentage of free PSA[J ]. Am J Clin Pathol, 2008,129(6) : 952 - 958.
  • 6Bomer OP. Standardization, specificity, and diagnostic sensitivity of four immunoassays for carcinoembryonic antigen [ J J. Clin Chem, 1991. 37(2) :231 - 236.
  • 7吴健民.影响肿瘤标志物检测的因素[J].中华检验医学杂志,2005,28(4):352-354. 被引量:22
  • 8申子瑜.医院管理学(临床实验室管理分册)[M].北京:人民卫生出版社,2003.58-87.

二级参考文献24

  • 1童清,王清涛.临床化学定量测定室间质量评价的有关问题[J].中华检验医学杂志,2005,28(2):131-133. 被引量:36
  • 2陈文祥,申子瑜,郭健,杨振华.临床检验量值溯源中的重要术语与概念及有关问题[J].中华检验医学杂志,2005,28(2):142-146. 被引量:35
  • 3Selby C. Interference in immunoassay. Ann clin Biochem,1999.36:704-721.
  • 4李金明.肿瘤标志物免疫测定的质量控制及标准化[A]..肿瘤标志专题讨论会论文集[C].,2002.41-53.
  • 5Sturgeon CM, Seth J. Why do immunoassays for tumor markers give differing results?--a view from the UK National External Quality Assessment Schemes. Eur J Clin Chem Biochem, 1996, 34:755-759.
  • 6Sturgeon CM. Tumor markers in the laboratory: closing the guideline-practice gap. Clin Biochem, 2001,34:353-359.
  • 7Wood WG. "Matrix effects" in immunoassay. Scan J Clin Lab Invest Suppl, 1991,205:105-112.
  • 8Bidart JM, Thuillier F, Augereau C, et al. Kinetics of serum tumor marker concentrations and usefulness in clinical monitoring. Clin chem,1999,45:1695-1707.
  • 9Sciacovelli L, Secchiero S, Zardo L, et al. External Quality Assessment Schemes: need for recognised requirements. Clin Chim Acta, 2001,309 : 183-199.
  • 10Miller WG. Specimen materials, target values and commutability for external assessment (proficiency testing) schemes. Clin Chim Acta, 2003, 327 : 25-37.

共引文献54

同被引文献5

引证文献2

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部