摘要
研究选择性催化还原法(SCR)在330MW燃煤电厂上的应用,分析了SCR系统工艺流程、工作原理及影响脱硝效率的因素。经过较长时间稳定运行,系统脱硝效率在80%以上,达到设计参数,为燃煤电厂NOx控制提供参考。
This essay studies the application of SCR in 330MW units in coal-fired power plants as well as analyzing its technological process,its working principles and the factors which affect the denitration efficiency. After a long period of stable operation,the denitration efficiency is above 80%. The index reaches the expected design parame- ter,which provides reference for NOx control in coal-fired power plants.
出处
《重庆电力高等专科学校学报》
2012年第3期87-89,共3页
Journal of Chongqing Electric Power College