摘要 利用高斯—牛顿法求解便携关节式坐标测量机的标定参数时,其参数的可辨识性与Jacobin矩阵的条件数有关,而Jacobin矩阵的条件数决定于标定采样点的坐标。因此,必须对参数标定的采样策略进行优化。文中以锥孔标准杆件标定法为例,提出一种优化的采样策略来增大各个关节取值范围,从而使条件数最小化。经实验验证,采用这种优化采样策略标定提高了测量系统的精度。 We use the Gauss-Newton method to find the parameters in the parameters calibration for PCMM (Portable Coordinate Measuring Machine). Then we find the relationship between the identification of parameters and the conditions numbers of Jacobin Matrix, and in practical the conditions numbers of Jacobin Matrix depends on the sample point. Therefore, the sampling strategy must be optimized. Using the cone and standard bar as a calibra- tion standard, this paper presents an optimized sampling strategy to increase the value range of each joint and thus minimize the conditions number of Jacobin Matrix. Experiment results show that the sampling strategy of calibration greatly improves the measurement accuracy.
作者 奚思 于连栋
出处 《电子科技》 2012年第8期132-134,共3页 Electronic Science and Technology
基金 国家自然科学基金资助项目(51075117)
关键词 参数标定 采样策略 高斯-牛顿法 条件数 parameters calibration sampling strategy Gauss-Newton the conditions numbers
  • 相关文献

参考文献3

二级参考文献9

  • 1魏霖,王从军.多关节坐标测量机的坐标转换和参数标定[J].光电工程,2007,34(5):57-61. 被引量:15
  • 2Adams L. Competition rising in portable CMMs[J]. Quality Measurement Test and Inspection, 2002, 7: 18-22.
  • 3Yang Xiao-jun, Li Bing, Zhang Dong-lai. Kinematics Calibration of parallel kmematic machine using a developed double-ball bar gauge[J]. Key Engineering Materials, 2008, 364-366 :243-248.
  • 4Shimojima K, Furutani R, Takamasu K, et al. The estimation method of uncertainty of articulated coordinate measuring machine [C]//IEEE ICIT'02, Bangkok, Thailand, 2000:411-415.
  • 5Lightcap C, Hamner S, Schmitz T, et al. Improved positioning accuracy of the PA10-6CE robot with geometric and flexibility calibration [ J ]. IEEE Transactions on Robotics, 2008,24(2) : 452-456.
  • 6Alici G, Shirinzadeh B. A systematic technique to estimate position errors for robot accuracy improvement using laser intefferometry based sensing [J].Mechanism and Machine Theory, 2005,40(8) : 879-906.
  • 7Bai Y, Zhuang H, Roth Z. Experiment study of PUMA robot calibration using a laser tracking system[C]// Proceedings of the 2003 IEEE International Workshop on Soft Computing in Industrial Applications. IEEE, 2003:139-144.
  • 8Danavit J, Hartenberg R S. A kinematic notation for lower pair mechanisms based on matrices [J].ASME Journal of Applied Mechanics, 1955,22 (2) : 215-221.
  • 9Brank K, Miomir V. Calibration and accuracy of manipulation robot models-an overview [J]. Mech Maeh Theory, 1994,29(3): 479-500.

共引文献12

同被引文献24

  • 1汪平平,费业泰,林慎旺.柔性三坐标测量臂的标定技术研究[J].西安交通大学学报,2006,40(3):284-288. 被引量:31
  • 2徐卫,马履中,郭宗和,马晓丽.三平移并联机器人坐标测量机精度研究[J].农业机械学报,2006,37(5):122-124. 被引量:3
  • 3王学影,刘书桂,张洪涛,张国雄.多关节柔性三坐标测量系统误差分析研究[J].传感技术学报,2007,20(2):435-438. 被引量:8
  • 4汪平平,费业泰,尚平,程文涛.柔性坐标测量机参数辨识方法[J].农业机械学报,2007,38(7):129-132. 被引量:14
  • 5LARRY A. Competition rising in portable CMMs[J].Quality Measurement/Test/Inspection,2002,(07):18-22.
  • 6KAVAV I,KLEIN A. Apparatus and a procedure to calibrate coordinate measuring arms[J].strojniski vestnik-journal of mechanical engineering,2002,(01):17-32.
  • 7AGUILAR J J,SANTOLARIA J,YAGUE J A. Calibration,non-geometric error modelling and correction methods for articulated arm coordinate measuring machines[J].International Journal of Mechatronics and Manufacturing Systems,2011.49-60.
  • 8叶 东.多关节坐标测量机的理论和技术[D]哈尔滨:哈尔滨工业大学,1999.
  • 9HAMANA H,TOMINAGA M,OZAKI M. Calibration of articulated arm coordinate measuring machine considering measuring posture[J].International Journal of Automotive Technology,2011,(02):109-110.
  • 10SANTOLARIA J,AGUILAR J J,YAGRE J A. Kinematic parameter estimation technique for calibration and repeatability improvement of articulated arm coordinate measuring machines[J].Precision Engineering,2008,(04):251-268.

引证文献2

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部