围绕解决工业区存在的谐波和电压暂降问题,以一个冲压成型厂为例,阐述了电压暂降给企业的生产带来的危害。并提出利用FLUKE仪器来监测工业区电压暂降的方法。最后,结合电网的实际情况,针对该地区提出降低谐波和电压暂降影响造成损失的策略。
To solve the existing problem around industrial harmonic and voltage sag.A punch forming factory as an example, expounded the voltage sag to the harm of the production of the enterprise.And this paper put forward a method to monitor industrial zone of voltage sag by the FLUKE instruments.At last, by summarizing the above analysis and actual situation of the grid, strategies were proposed to improve harmonics and voltage sag in this area.
出处
《电子世界》
2012年第15期61-62,共2页
Electronics World