摘要 在分析了原位检测系统中触发式测头误差来源的基础上,提出了自动调整测头偏心的方法,并用标定球对测头的实际作用半径进行了校准。同时,面向实际测量任务,提出了基于在线标定和双线性插值技术的逐点测头半径补偿方法,实验验证,所提出的半径补偿方法比商用软件提供的方法更准确,提高了测量结果的准确性。 On the basis of analysis on the errors from touch trigger probe o{ OMM, a method tocorrect the offset of probe was given, and the actual effective radius o{ probe was calibrated by means of a calibration ball. Oriented to practical measurement task, a new probe radius compensation meth- od based on on--line calibration and bilinear interpolation techniques was presented. The verification experiments of radius compensation show that the accuracy by this method, compared to the method provided by the commercial software, can be much improved.
出处 《中国机械工程》 EI CAS CSCD 北大核心 2012年第15期1774-1778,共5页 China Mechanical Engineering
基金 国家重点基础研究发展计划(973计划)资助项目(2011CB706804) 国家自然科学基金资助重点项目(50835004)
关键词 原位检测 触发式测头 在线标定 半径补偿 on--machine measurement(OMM) touch trigger probe on--line calibration radiuscompensation
  • 相关文献

参考文献12

  • 1Mears L, Roth J T, Djurdjanovic D, et al. Quality and Inspection of Machining Operations:CMM Integration to the Machine Tool[J]. Journal of Manufacturing Science and Engineering, 2009, 131 (5) 051006.
  • 2Cho M W,Kim G H,Seo T. Integrated Machining Error Compensation Method Using OMM Data and Modified PNN Algorithm[J]. International Journal of Machine Tools and Manufacture, 2006,46 (12/13) :1417-1427.
  • 3Zeleny J,Janda M. Automatic On-machine Measurement of Complex Parts[J]. Modern Machinery Science Journal, 2009,3: 92-95.
  • 4李斌,孙忠林,彭芳瑜,李海洲.叶片零件在线检测测点规划问题研究[J].中国机械工程,2008,19(5):540-542. 被引量:12
  • 5Weckenmann A, Estler T, Peggs G, et al. Probing Systems in Dimensional Metrology[J]. CIRP Annals-Manufacturing Technology, 2004,53 (2) : 657-684.
  • 6Estler W T,Phillips S D,Borchardt B,et al. Error Compensation for CMM Touch Trigger Probes[J]. Precision Engineering, 1996,19(2/3): 85-97.
  • 7Wozniak A,Dobosz M. Influence of Measured Objects Parameters on CMM Touch Trigger Probe Accuracy of Probing[J]. Precision Engineering, 2005, 29 (3): 290-297.
  • 8刘丽冰,刘又午,赵小松,章青,方沂.加工中心在线检测误差补偿技术研究[J].中国机械工程,2000,11(3):313-316. 被引量:25
  • 9Xiong Zhenhua,Li Zexiang. Probe Radius Compensation of Workpiece Localization [J]. Journal of Manufacturing Science and Engineering, 2003, 125 (1): 100-104.
  • 10Srinivasan S, Kovvur Y, Anand S. Probe Radius Compensation for On-machine Measurement of Sculptured Surfaces [C]// Proceedings of ASME International Mechanical Engineering Congress and Exposition. Anaheim, CA, USA, 2004: 913- 920.

二级参考文献13

  • 1范裕健,赵卓贤.圆柱面形状误差评定的理论与方法[J].机械工程学报,1994,30(2):19-25. 被引量:16
  • 2梁任,伍正祥.坐标测量的抽样点数、分布与精度[J].机械工程学报,1994,30(4):29-35. 被引量:7
  • 3华玉亮,盛伯浩.触发式测头全方位精密测量技术[J].制造技术与机床,1994(4):11-14. 被引量:10
  • 4梅向明,黄敬立.微分几何[M].北京:高等教育出版社,1985
  • 5Li S Z. Adaptive Sampling and Mesh Generation[J]. ComputerAided Design,1995, 27(3): 235-240.
  • 6Edgeworth R, Wilhelm R G. Adaptive Sampling for Coordinate Metrology[J]. Precision Engineering 1999, 23:144-154.
  • 7Menq C--H, Yau H--T, Lai G--Y. Automated Precision Measurement of Surface Profile in CAD Directed Inspection[J]. IEEE Transactions on Robotics and Automation,1992, 8(2) : 268-278.
  • 8Lee G, Mou J, Shen Y. Sampling Strategy Design for Dimensional Measurement of Geometric Features Using Coordinate Measuring Machine [J]. Int. J. Mach. Tools Manufacture, 1997,37(7) :917-934.
  • 9Choi W, Kurfess T R,Cagan J. Sampling Uncertainty in Coordinate Measurement Data Analysis[J]. Preci sion Engineering, 1998,22: 153-163.
  • 10国家技术监督局.GB12916-91船用金属螺旋桨技术条件[S].1991.

共引文献34

同被引文献83

引证文献15

二级引证文献58

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部