期刊文献+

火力发电厂风机变频节能分析和运行措施 被引量:2

Analysis on energy-saving effect of variable frequency technology for draught fans of thermal power plants and operational measures
下载PDF
导出
摘要 对华电四川发电有限公司攀枝花分公司2台150 MW循环流化床机组锅炉风机实施了变频技术改造,通过对风机设备改造前、后能耗指标对比分析,提出了节能改造技术措施,有效降低厂用电率,提高了经济效益。 Using the variable frequency technology,the driving systems of the draught fans of two 150MW CFB boilers in Panzhihua Branch of Huadian Sichuan Power Generation Corporation Limited were reformed.Based on comparative analysis on the energy consumption indexes of the fans before and after the reformation,the technical measures of energy-saving reformation were put forward.So the service power consumption rate was reduced effectively,and the economic benefit was improved.
作者 王绍平
出处 《华电技术》 CAS 2012年第7期62-64,81,共3页 HUADIAN TECHNOLOGY
关键词 发电厂 变频技术 厂用电率 改造 节能 措施 power plant variable frequency technology service power consumption rate reformation energy-saving measure
  • 相关文献

参考文献1

  • 1徐海,施利春.变频原理及应用[J].北京:清华大学出版社,2010.

同被引文献8

引证文献2

二级引证文献6

相关作者