摘要
依据JJG 1036–2008《电子天平检定规程》,分析了电子天平示值误差测量结果不确定度的来源,以最大称量点200 g为例,对不确定度分量进行了评定与计算。当最大称量为200 g时,扩展不确定度为0.18 mg(k=2)。
The sources of measurement uncertainty of electronic balance indication error were analysed according to JJG 1036-2008 Electronic Balance Verification Regulation. The largest weighing 200 g was taken for example, uncertainty components were calculated. The expanded uncertainty was 0.18 mg(k=2.01) as the largest weighing was 200 g.
出处
《化学分析计量》
CAS
2012年第4期20-21,共2页
Chemical Analysis And Meterage
关键词
电子天平
示值误差
不确定度
electronic balance
indication error
uncertainty