摘要
结合响水涧抽水蓄能电站的实际,对一种新型离相封闭母线防结露装置的应用进行探讨,为防止离相封闭母线结露提供一些参考和借鉴。主要介绍FAD-02型强迫循环空气干燥系统的工作原理、控制流程、工作流程以及该套装置的系统组成、功能和特点。联系15.75kV离相封闭母线接线方式,介绍该装置在电站的配置情况,对运行情况进行简要分析,对干燥系统的实际应用提出改进建议。
Combining practical application in Xiangshuijian Pumped Storage Power Station,a new-type condensation prevention device application in isolated-phase enclosed busbar is discussed in hopes of providing reference for condensation prevention in isolated-phase enclosed busbar.The following content about FAD-02 forced circulating air drying system is introduced,including working principle,control flow,work flow,system compositon,function,characteristic.Integrating the mode of 15.75 kV isolated-phase enclosed busbar connection,the device allocation in the power station is introduced.The running situation is analyzed briefly.In the end,the suggestions for improvement is proposed for practical application.
出处
《中国农村水利水电》
北大核心
2012年第7期164-166,共3页
China Rural Water and Hydropower
关键词
离相封闭母线
强迫循环
原理
配置
改进建议
isolated-phase enclosed busbar
forced circulating
principle
allocation
suggestions for improvement