介绍了混凝沉淀+离子交换法处理贵金属加工废水的工程设计、施工以及运行情况。该系统自投入以来,运行稳定,操作简单,维护方便,处理效果好,出水水质远远优于广东省地方标准《水污染物排放限值》(DB44/26-2001)第二时段一级标准。
Introduced the precious metals processing wastewater treatment engineering design,construction and operation by coagulation precipitate + ion exchange method.Since input,the system has stable operation,simple operation,convenient maintenance,effective treatment,treated water was far superior to the Guangdong Local Standards "Water Pollutants Emission Limits"(DB44/26-2001) the second time level standard.
出处
《广东化工》
CAS
2012年第8期62-62,33,共2页
Guangdong Chemical Industry
关键词
混凝沉淀
离子交换
污水处理
coagulation precipitate
ion exchange
sewage treatment