摘要 采用电位滴定法同时标定硫酸高铈标准溶液和硫酸亚铁铵标准溶液。以草酸钠为基准物质,通过对电位滴定装置的改进,在被滴定溶液与盐桥之间增加了一个一端封有磺酸型离子膜、内部注入2mol.L-1硫酸溶液的玻璃管,用来阻隔盐桥与被滴定溶液间的物质交换。方法用于硫酸高铈和硫酸亚铁铵溶液的标定,测定值的相对偏差为0.55%,表明方法具有高精度。 The standard solutions of Ce (SO4) 2 and ( NH4 ) 2 Fe (SO4) 2 were standardized simultaneously by potentiometric titration. Sodium oxalate was used as primary standard. In order to avoid the interference of mass exchange between the salt bridge and the measured solution with the result of titration, the titration device was modified. An/on-exchange membrane was set between the salt bridge and measured solution to depress the mass exchange at the interface. It was found that high precision was attained by the present method, giving values of relative deviation between the determined values of the 2 standard solution of 0. 55 %.
出处 《理化检验(化学分册)》 CAS CSCD 北大核心 2012年第7期841-844,共4页 Physical Testing and Chemical Analysis(Part B:Chemical Analysis)
基金 浙江省科技厅(创新团队)项目(2011R09002-05)
关键词 电位滴定法 同时标定 硫酸高铈溶液 硫酸亚铁铵溶液 Potentiometric titration Simultaneous standardization Ce ( SO4 ) 2 solution ( NH4 ) 2 Fe ( SO4 ) 2solution
  • 相关文献

参考文献10

二级参考文献26

  • 1彭声谦,许国镇,杨华栓,董栋.用从石煤中提取的V_2O_5制备钒电池用VOSO_4的研究[J].无机盐工业,1997,11(1):3-6. 被引量:33
  • 2顾琅(译).澳大利亚驻中国大使馆[J].世界产品与技术,1998,(1):45-45.
  • 3王泽伟.化验员新技术与操作规范化实用大全(Ⅱ),天津:电子出版社,2005.814
  • 4薛潮明.分析化学,北京:地质出版社,1995.250
  • 5邢文卫,田景君.分析化学,北京:化学工业出版社,1982.468
  • 6《英国药典》.2007[S].Vol Appendix I B.
  • 7《美国药典》31[S].Vol 1 Solutions / Volumetric solutions 821.
  • 8《日本药局方》[S].General Tests 9.21 Standard Solutions for Volumetric Analysis 132.
  • 9化学试剂标准汇编[M].基础标准和基础标准试剂卷(2005),中国标准出版社,GB/T601-2002.
  • 10Rydh C J. Environmental assessment of vanadium redox and lead-acid batteries for stationary energy storage[J]. J Power Sources, 1999, 80(1-2):21-29.

共引文献141

同被引文献56

引证文献3

二级引证文献38

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部