鞍形垫板加强T形相贯节点极限承载力分析 被引量:5

Numerical Method of Ultimate Capacity of Doubler Plate Reinforced Tubular T-joints
下载PDF
导出
摘要 利用有限元分析方法对鞍形垫板加强T形相贯节点在支管轴向拉力和压力作用下的极限承载力进行了研究,并在现行钢结构设计规范中关于直接焊接相贯节点的极限承载力设计公式的基础上引入极限承载力提高系数φ建立垫板加强T形相贯节点极限承载力设计公式.分析结果表明,支管轴向拉力作用下,影响φ的主要参数为垫板厚度λ;支管轴向压力作用下,影响φ的主要参数为主支管直径比β和垫板厚度λ. Finite element method is adopted in the numerical parametric studies to evaluate the ultimate capacity of doubler(plate reinforced tubular T-joints under tensile loading or compress loading.Based on the design formula of un-reinforced tubular T-joints in the code for design of steel structure,parameter φ has been used to evaluate the ultimate bearing capacity of reinforced T-joints.Based on the analysis result,the following conclusions can be obtained: under tensile loading,the main effective parameter is doubler plate thickness ratio;under compression loading,the main parameters are chord to brace thickness ratio.
出处 《同济大学学报(自然科学版)》 EI CAS CSCD 北大核心 2012年第7期977-981,共5页 Journal of Tongji University:Natural Science
基金 同济大学土木工程国家重点实验室项目(SLDRCE08-A-04) 教育部留学人员科研启动基金(教外司留【2011】508号)
关键词 钢结构 T形相贯节点 鞍形垫板加强 极限承载力 有限元分析 steel structure T-joints reinforced by doubler plate ultimate bearing capacity finite element analysis
  • 相关文献

参考文献7

  • 1Packer J A, Henderson J E. Hollow structural section connections and trusses--a design guide[M]. 2nd ed. Toronto: Canadian Institute of Steel Construction, 1997.
  • 2Fung T C, Chan T K, Soh C K. Ultimate capacity of doubler plate reinforced tubular joints [J ]. Journal of Structural Engineering, 1999, 125(8) : 891.
  • 3Choo Y S, Van der vegte G J, Zettlemoyer N, et al. Static strength of T-joints reinforced with doubler or collar plates. I: experimental investigations [ J ]. Journal of Structural Engineering, 2005, 131(1) : 119.
  • 4G J Van der Vegte,Choo Y S,Liang J X,et al. Static strength of T-joints reinforced with doubler or collar plates. Ⅱ: numerical simulations[J]. Journal of Structural Engineering, 2005,131 (1) : 129.
  • 5吴亮秦,李自林,韩庆华.垫板加强N形圆钢管相贯节点静力性能试验研究[J].建筑结构学报,2010,31(10):83-88. 被引量:20
  • 6Chiew S P, Soh C K, Fung T C. Large-scale testing of a multiplanar tubular DX-joint[C]. Proceeding 7th International Conference on Offshore Mechanics and Arctic Engineering 3. New York:ASME, 1997:313-319.
  • 7Yura J A, Zettlemoyer N, Edwards I F. Ultimate capacity of circular tubular joints[J]. Journal of the Structural Division, 1981,107: 1965.

二级参考文献15

  • 1舒兴平,朱正荣,王元清.N型方圆钢管相贯节点足尺试验研究[J].建筑结构学报,2006,27(1):66-70. 被引量:27
  • 2赵宏康,戴雅萍,吕西林.苏州国际博览中心屋盖结构分析和并联K形圆钢管相贯节点研究[J].建筑结构学报,2006,27(4):51-60. 被引量:13
  • 3Packer J A,Henderson J E.空心管结构连接设计指南[M].曹俊杰,译.北京:科学出版社,1997.
  • 4Dexter E M, Lee M M K. Static strength of axially loaded tubular K-joints : I : Behavior [ J ]. Journal of Structural Engineering, ASCE, 1999,125 (2) : 194-201.
  • 5Dexter E M, Lee M M K. Static strength of axially loaded tubular K-joints: II: Ultimate capacity [ J ]. Journal of Structural Engineering, ASCE, 1999, 125 (2) :202-210.
  • 6Choo Y S, Qian X D, Wardenier J. Effects of boundary conditions and chord stresses on static strength of thick- walled CHS K-joints [ J ]. Journal of Constructional Steel Research ,2006,62 : 316-328.
  • 7Ai K, Chee S K. Stress analysis of axially loaded T tubular joints reinforced with doubler plates [ J ]. Computer & Structure,1993,55( 1 ) :141-149.
  • 8Packer J A. Concrete filled HSS connections [ J ]. Journal of Structural Engineering, ASCE, 1995, 121 ( 3 ) :458-467.
  • 9Sakai Y, Hosaka T, Isoe A. Experiments on concrete filled and reinforced tubular K-joints of truss girder[ J]. Journal of Constructional Steel Research, 2004,60 ( 3- 5) :683-699.
  • 10Choo Y S, van der Vegte G J, Zettlemoyer N, et al. Static strength of T-joints reinforced with doubler or collar plates : I: Experimental investigations [ J ]. Journal of Structural Engineering, ASCE, 2005, 131 (1) :119-128.

共引文献19

同被引文献99

引证文献5

二级引证文献39

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部