期刊文献+

基于故障电压比较的广域后备保护新算法 被引量:23

A Novel Wide Area Backup Protection Algorithm Based on Fault Voltage Comparison
下载PDF
导出
摘要 提出了一种基于故障电压比较的广域后备保护新算法,有助于解决传统后备保护整定配合复杂,潮流转移时易误动等问题。该算法利用线路一侧电压、电流故障分量的测量值推算另一侧电压故障分量,以推算值与测量值的比值识别故障元件。并通过故障区域检测降低广域信息传输量,加快故障元件识别速度。该算法原理简洁,对保护范围内多点量测数据的同步性要求较低。基于川渝500kV电网测试系统的仿真结果表明,该算法在电网高阻接地、非全相运行、故障转换及重负荷转移等情况下均具有良好的动作性能。 A novel wide area backup protection algorithm based on fault voltage comparison is presented in this paper, which is helpful to overcome the problems of conventional backup protection about complex setting and mal-operation under flow transfer. Measured voltage and current fault components from one terminal of transmission line are provided to estimate the voltage fault components of the other terminal. Then the fault element is identified by means of the ratio of measured and estimated value. Meanwhile, the speed of fault element identification can be accelerated by fault area detection scheme. This method depends on easy setting and lower demand to wide area data synchronism. The simulation test based on Chuan-yu 500kV grid test system showes the validity of proposed method under various complex conditions, such as high impedance earth fault, open-phase operation, evolved fault and flow transfer.
出处 《电工技术学报》 EI CSCD 北大核心 2012年第7期274-283,共10页 Transactions of China Electrotechnical Society
基金 国家自然科学基金(50837002 50877031) 国家高技术研究发展计划(863计划)(2009AA05Z208) 高等学校博士学科点专项科研基金(20090142110055)资助项目
关键词 故障元件识别 故障区域检测 故障电压比值系数 有限广域 广域后备保护 Fault element identification, fault area detection, fault voltage ratio coefficient, limitedwide area, wide area backup protection
  • 相关文献

参考文献17

  • 1Horowitz S H, Phadke A G. Third zone revisited[J]. IEEE Transactions on Power Delivery, 2006, 21(1): 23 -29.
  • 2Novosel D, Bartok G, Henneberg G, et al. IEEE PSRC report on performance of relaying during wide-area stressed conditions[J]. IEEE Transactions on Power Delivery, 2010, 25(1): 3-16.
  • 3Adamiak M G, Apostolov A P, Begovic M M, et al Wide area protection-technology and infrastructures[J] IEEE Transactions on Power Delivery, 2006, 21(2) 601-609.
  • 4Phadke A G, Thorp J S. Synchronized phasor measurements and their applications[M]. NY, USA: Springer, 2008.
  • 5Su S, Li K K, Chan W L, et al. Agent based self-healing protection system[J]. IEEE Transactionson Power Delivery, 2006, 21(2): 610-618.
  • 6Tong X Y, Wang X R, Hopkinson K M. The modeling and verification of peer-to-peer negotiating multiagent colored protection[J]. IEEE 2009, 24(1): 61-72. petri nets for wide-area backup Transactions on Power Delivery,.
  • 7马静,李金龙,王增平,杨奇逊.基于故障关联因子的新型广域后备保护[J].中国电机工程学报,2010,30(31):100-107. 被引量:35
  • 8Lin X N, Li Z T, Wu K C, et al. Principles and implementations of hierarchical region defensive systems of power grid[J]. IEEE Transactions on Power Delivery, 2009, 24(1): 30-37.
  • 9丛伟,潘贞存,赵建国.基于纵联比较原理的广域继电保护算法研究[J].中国电机工程学报,2006,26(21):8-14. 被引量:126
  • 10汪旸,尹项根,张哲,刘建,何志勤.基于遗传信息融合技术的广域继电保护[J].电工技术学报,2010,25(8):174-179. 被引量:62