摘要
建立了一种用高效液相色谱测定氟环唑的定量分析方法。采用C18HPLC色谱柱,以甲醇乙腈水(4∶4∶3)为流动相,205nm检测波长下进行检测。结果表明,该方法的相对标准偏差为0.23,相关系数γ为0.999 7。
To establish a quantitative HPLC procedure for epoxiconazole analysis using a C18 HPLC column. The con-sists of the fluid were methanol, acetonitrile and water(4 : 4 : 4), and was determinated at 205 nm. Relatively standard deviation was 0. 23 ,linear regression coefficient was 0. 999 7.
出处
《河北化工》
2012年第8期87-88,共2页
Hebei Chemical Industry