摘要
根据深圳地铁工程维护车技术要求,从导流截面积、簧片的接触压力、主回路温升以及限位弹簧参数等方面对隔离接地开关进行设计计算,确保设计满足标准和用户要求。
According to the technical requirements of Shenzhen subway maintenance locomotive,diversion cross-sectional area,contact pressure on the spring contact,temperature rise in main circuit and parameter of limited location spring are calculated. This product meets design standards and user's requirements.
出处
《电力机车与城轨车辆》
2012年第4期38-40,共3页
Electric Locomotives & Mass Transit Vehicles
关键词
隔离接地开关
计算
截面积
温升
限位弹簧
disconnecting and earthing switch
calculation
cross-sectional area
temperature rise
limited location spring