摘要 模拟移动床(SMB)色谱分离与纯化的操作过程复杂,对其进行设计与优化需要使用数值模拟方法,准确测定竞争型吸附等温线具有重要意义。采用逆向法确定了25℃下酮洛芬对映体在直链淀粉手性固定相(Chiralpak AD)上的竞争吸附等温线,先用高效液相色谱测得酮洛芬对映体在Chiralpak AD柱上的过载流出曲线,再通过拟合实验测得的流出曲线确定吸附等温线模型及其参数。研究中采用平衡扩散模型描述酮洛芬对映体在色谱柱上流出的瞬态过程。参数拟合过程中,首先用非支配基因算法(NSGA-Ⅱ)在较广的参数空间内搜索吸附等温线模型参数,再以所得结果作为初值,使用Levenberg-Marquardt算法(LMA)对参数进一步优化。比较了4种不同竞争吸附等温线模型对实验测得的流出曲线的拟合结果,其中五参数的Bi-Langmuir模型拟合程度最好。测量了不同进料浓度和进料量条件下的流出曲线,并通过与模型预测结果的对照验证了所确定吸附等温线模型和参数。 The determination of competitive adsorption isotherm is of great importance for model-based design and optimization of chromatographic separation processes,especially for the simulated moving bed due to its intrinsic complexity.The competitive adsorption isotherms of ketoprofen enantiomers on an amylose-based chiral stationary phase(Chiralpak AD)at 25℃ were determined in this study by the application of the inverse method.Elution profiles of various racemic feed signals were measured on a preparative chromatography column with a precise temperature control system.The parameters of isotherm models were determined by fitting the experimental elution profiles.The mass balance for component in the column was described by equilibrium-dispersive model.In the fitting procedure,isotherm parameters were searched over a wide range in the parametric space with the non-dominated sorting genetic algorithm(NSGA-Ⅱ)and polished with the Levenberg-Marquardt algorithm.Four competitive adsorption isotherm models were compared based on the fitting to the experimental data.Bi-Langmuir model with 5 parameters gave the best results.In order to validate this model and the model parameters,independent overloaded profiles with different concentrations and amount of feed were measured and compared with the model.Quantitatively good agreement was observed.
出处 《化工学报》 EI CAS CSCD 北大核心 2012年第8期2469-2476,共8页 CIESC Journal
基金 国家自然科学基金项目(21106108)~~
关键词 竞争吸附等温线 酮洛芬对映体 逆向法 模拟移动床色谱 competitive adsorption isotherm; ketoprofen enantiomers; inverse method; SMB
  • 相关文献

参考文献4

二级参考文献23

  • 1Guest D W.Evaluation of simulated moving bed chromatography for pharmaceutical process development.J. Chromatogr. A,1997,760:159-162.
  • 2Strube J, Jupke A, Epping A, Traub H E, Schulte M, Devant R.Design, optimization, and operation of SMB chromatography in the production of enantiomerically pure pharmaceuticals.Chirality,1999,11:440-450.
  • 3Pais L S, Loureiro J M, Rodrigues A E.Separation of enantiomers of a chiral epoxide by simulated moving bed chromatography.J. Chromatogr. A,1998,827:215-233.
  • 4Juza M, Mazzotti M, Morbidelli M. Simulated moving bed chromatography and its application to chirotechnology.Trends in Biotechnology,2000,18:108-118.
  • 5McCoy M. SMB emerges as chiral technique.Chem. & Eng. News,2000,19:17-19.
  • 6Mazzotti M, Storti G, Morbidelli M.Optimal operation of simulated moving bed for nonlinear chromatographic separation.J. Chromatogr. A,1997,769:3-24.
  • 7Migliorini C, Mazzotti M, Morbidelli M.Design of simulated moving bed multicomponent separation:langmuir systems.Separation and Purification Technology,2000,20:79-96.
  • 8Okamoto Y, Kawashima M, Hatada K.Chromatographic resolution:Ⅺ.Controlled chiral recognition of cellulose triphenyl carbamate derivatives supported on silica gel. J. Chromatogr.,1986,363:173-186.
  • 9Felinger A,Cavazzini A,Guiochon G.Numerical determination of the competitive isotherm of enantiomers.J.Chromatogr A.,2003,986(2):207-225
  • 10Zhou D M,Kaczmarski K,Guiochon G.Comparison of the binary equilibrium isotherms of the 1-indanol enantiomers on three high-performance liquid chromatography columns of different sizes.J.Chromatogr A.,2003,1015(1):73-87

共引文献36

同被引文献32

引证文献6

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部