EPID在盆腔肿瘤放疗中的摆位误差分析 被引量:2

Positioning error analysis of EPID in the radiotherapy of pelvic tumors
下载PDF
导出
摘要 目的:分析电子射野影像系统(EPID)在盆腔肿瘤放疗中的摆位误差。方法:选取进行盆腔肿瘤放疗的患者40例,使用EPID所拍摄的正位和侧位片与数字化重建图像的验证片进行对照,计算并分析量化所测定的摆位误差。结果:前后和头脚的误差范围明显大于左右,而前后平均误差值明显大于头脚和左右的平均误差值,在3 mm以下左右和头脚摆动误差的发生率明显高于前后。结论:利用EPID可以有效检测盆腔肿瘤放疗的摆位误差,提高摆位的准确性和重复性,从而保证盆腔肿瘤放疗的质量。 Objective To analyze EPID in the replacement errors of radiotherapy pelvic tumor.Methods Select pelvic radiotherapy of tumor receiving our cases of 40 cases all cases.The treatment of EPID to capture the anteroposterior and lateral films,and digital image reconstruction verification films were analyzed to calculate the error.Results Before and after of the error range significantly greater than right-and-left, so is head and feet.the Before and after average error value significantly greater than the others,in the following 3 mm about feet and head swinging the incidence of error significantly higher than before and after, so is fight-and-leit.Conclusion Using EPID can detect effectively pelvic radiotherapy of tumor to replacement errors and to increase accuracy and repeatability of replacement, so as to ensure the quality of the pelvic radiotherapy of tumor.
作者 贾国峰
出处 《吉林医学》 CAS 2012年第21期4491-4492,共2页 Jilin Medical Journal
关键词 EPID 盆腔肿瘤 放射治疗 摆位误差 EPID Pelvic tumor Radiation therapy Replacement errors
  • 相关文献

参考文献4

二级参考文献12

  • 1王艳阳,傅小龙.CT在影像引导下放疗中应用的历史与现状[J].中国癌症杂志,2006,16(6):448-453. 被引量:22
  • 2Prescribing recording and reporting photon bean1 therapy(Supplement to ICRU report 50)[R]. ICRU. Report no.62,1999.
  • 3Van Herk M, Remeijer P. Lebesque jr. Inclusion of geometric uncertainties in treatment plan evaluation [J]. Int J Radiat Oncol Biol Phys, 2002,52(5): 1407-1422.
  • 4Mckenzie A, Van Herk M, Mijnheer B. Margins for geometric uncertainty around organs at risk in radiotherapy [J]. Radiotherapy and Oncology, 2002,62(3):299-307.
  • 5Hurkmans CW, Remeijer P'Lebesque JV, et al. Set-up verification using portal image review of current clinical practice [J]. Radiotherapy and Oneology, 2001,58(2):105-120.
  • 6Stroom JC, de Boer HC, Huizenga H, et al. Inclusion of geometrical uncertainties in radiotherapy treatment plan ning by means of coverage probability[J]. Int J Radiat Oncol Biol Phys, 1999,43(4):905-919.
  • 7Dawson LA, Jaffray DA. Advances in image-guided radiation therapy. J Clin Oncol, 2007,25(8) :938-946.
  • 8Herman MG. Clinical use of electronic portal imaging. Semin Radiat Oncol, 2005, 15(3) : 157-167.
  • 9van Herk M, Remeijer P, Rasch C, et al. The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy. Int J Radiat Oncol Biol Phys, 2000, 47 (4): 1121-1135.
  • 10Borst GR, Sonke JJ, Betgen A, et al. Kilo-voltage cone-beam eomputed tomography setup measurements for hmg cancer patients ; first clinical results and comparison with electronic portal-imaging device. Int J Radiat Oneol Biol Phys, 2007, 68(2) :555-561.

共引文献68

同被引文献11

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部